2 Safety
06/2014
VG 766.2000.055
EN
35
– Attach a warning sign: "Do not switch on! The system is being
worked on."
– Ensure that the system is free of power.
Î
Check the electrical system regularly to ensure it is in proper
working condition.
2.7.4 Hot
surfaces
The electric motor can reach temperatures of up to 70 °C. There is a
risk of being burned.
Î
Do not touch the motor during operation.
Î
Allow the pump to cool down before servicing it.
2.7.5 Hazardous
materials
Î
Make sure that leaks of dangerous pumped fluids/gases are led
away without endangering people or the environment.
Î
Decontaminate the pump completely during disassembly.
2.7.6 Suction
danger
Ensure that the suction openings conform to current guidelines,
standards and instructions.
2.8 Defects
Î
In case of defects, immediately switch it off first and then remove
the system from operation.
Î
Have all defects repaired immediately.
Stuck pump
If a pump is stuck, and switched on several times repeatedly, the motor
can be damaged. Observe the following points:
Î
Do not switch the pump on repeatedly.
Î
Turn motor shaft, see Chapter 6.2, page 45
.
Î
Clean pump.