7 Defects
48
EN VG
766.2000.055
06/2014
If the motor shaft is difficult to turn:
1. Remove screwdriver.
2. Notify Customer Service and have the pump tested.
If the motor shaft is easy to turn:
1. Remove screwdriver.
2. Only open the valve on the delivery side
halfway
.
3. Reconnect to the power supply.
If the pump is stuck, the motor can be damaged if it is repeatedly
switched on.
Î
Ensure that the pump is only switched on once.
4. Wait until the built-in overload switch automatically switches on the
motor after it has cooled down.
– or –
Press the button of the built-in or external overload switch.
5. As soon as full motor speed is reached, open the valve on the
delivery side completely.
6. Have an electrician test power supply, fuses and power
consumption.
7. If the built-in or external overload switch switches off the motor
again, notify Customer Service.