Recharging is as follows:
Locate the quick release fitting next to the hydra-cushion
device. This should be fitted with a male ½” BSP fitting.
(see Figure 6.5.1.1)
Attach a suitable hydraulic hose to the fitting that has a
pressure gauge in the circuit.
Using a hydraulic pressure source (power pack, tractor
spool valve etc.), slowly add oil into the system until the
gauge reads 90 bar / 1305 PSI.
Vent any pressure in the system (the breakout circuit will
seal itself). Detach the quick release fitting and gauge
assembly, cleaning up any spilt oil.
Check the breakout function in operation. If after
recharging the breakout does not operate correctly, please
contact your nearest Spearhead authorised dealership.