24
Riomote® Control Operation
RIOMOTE
®
CONTROL
The
Riomote® remote control
provides the ability to operate the high pressure machine jetter from a
distance . There are multiple versions of the remote control based on the available functions of the machine .
EMERGENCY STOP TEST
Check that the emergency stop works before working with
the Riomote® control . Proceed as follows:
1 . Insert the key into the
eController key switch
.
2 . Turn the key to
position 2, Remote Control on
.
•
Work Safe
is displayed for 2 seconds .
•
Riomote® Control on
is displayed continuously .
• Corona illuminates blue and is blinking .
3 . Switch the Riomote® control
on
.
• Press and hold the
Start button
on the Riomote® to
link the Riomote® with the Urban Warrior .
• Release the
Start button
when the blue corona
stops blinking .
• Corona illuminates continuous blue when the
Riomote® control is in contact with the receiver .
4 . Start the engine using
Engine Start button
on the
Riomote® control .
5 . Depress the
Stop button
to exercise the Emergency
Stop function .
BATTERY INDICATION
If the
Battery indicator
on the Riomote control lights
continuously, the battery must be recharged .
NOTE!
If the engine does NOT stop by using the Riomote® control, contact Spartan Tool
Customer Service .
Battery
indicator
Start
Engine start
Emergency stop
Corona
eController
key switch
1
2
NOTE!
The engine will
shut down if the remote is
out of range or the battery
loses charge .