background image

13

NAVIGATION BULLETS

The navigation bullets have two general states: 

 

 

     Passive (gray)   

 

 

Active (blue)

Depending on the user’s location in the menu, one bullet is on display, or in the case of a pop-up eController error, all navigation bullets 
disappear . 

(See page 27, 

eController Errors

, for a list of pop-up displays.)

Features in navigation bullets are in specified order, if applicable:

The 

Error

 navigation icon is only visible and can 

be navigated when an error is applicable .

The 

Home

 navigation icon is the default position 

and normally displays engine run time and HP 
hose counter .

ECONTROLLER FUNCTIONS

When the eController is set to 

HP Hose Reel

 the LCD displays the 

hose position and the up/down control positions . The hose reel is 
actuated by rotating the Navigator dial clockwise to select 

down

 and 

counter clockwise to select 

up

 . Depress the Navigator dial to select 

the action .

The speed of the hydraulic drive using the eController is controlled 
by adjusting the speed control unit which throttles the hydraulic flow 
to the reel drive hydraulic motor . 

(See page 21, 

Rewind Hose Using 

Hydraulic Reel

.)

Hydraulic Speed Control

HP Hose Reel Mode

Description—Controls

Error

Home

HP Hose 

Reel

Management

When the eController is set to Management Mode, the LCD displays a menu of three functions that can 
be selected by rotating the Navigator dial and activated by depressing the navigation knob .

•  Software Version

 displays the current version of the controller software .

•  Service Interval

 displays the days and run hours until maintenance is required .

•  Hose Counter

 displays the length of hose off the HP hose reel .

Management Mode

Summary of Contents for 75720010

Page 1: ...GH CUSTOMERS PRODUCT MANUAL Urban Warrior Skid Mount Sewer Jetter 2018 Spartan Tool LLC Part 75720010 Spartan Tool LLC 1506 West Division Street Mendota IL 61342 order by phone 800 435 3866 order onli...

Page 2: ...Tachometer 14 Remote Control 15 SAFETY INSTRUCTIONS 16 IMPORTANT SYMBOLS 18 MECHANICAL OPERATION 19 Check Before Departure 19 Placement of Urban Warrior 19 Prior to Starting the Urban Warrior 19 Star...

Page 3: ...ne Temperature 28 Heat Exchanger High Temperature 28 Hydraulic Oil High Temperature 29 Oil Level 29 Coolant Level 29 Battery Charge 30 Run Dry 30 Service Interval 30 MAINTENANCE 31 Daily Maintenance 3...

Page 4: ...r boots with metatarsal guards and hearing protection Ensure the jet hose has been placed in the pipe minimum of 6 feet suggested before engaging the water pressure to prevent the hose from coming out...

Page 5: ...ion of machine LED dispay and warning lights provide machine status at a glance Pressure can be continuously adjusted with accessible handwheel Hose length counter Remote control 1 2 x 360 of Maxflow...

Page 6: ...essure regulator 12 Pressure gauge 13 Supply hose holder 14 Pivot Locking Device 15 Supply hose reel lock 16 Water filter valve 17 HP pump 18 Hydraulic oil reservoir 19 Pulsator valve 20 Water tank le...

Page 7: ...egulator 12 Pressure gauge 13 Supply hose holder 14 Pivot Locking Device 15 Supply hose reel lock 16 Water filter valve 17 HP pump 18 Hydraulic oil reservoir 19 Pulsator valve 20 Water tank level indi...

Page 8: ...gauge 13 Supply hose holder 14 Pivot Locking Device 15 Supply hose reel lock 16 Water filter valve 17 HP pump 18 Hydraulic oil reservoir 19 Pulsator valve 20 Water tank level indicator 21 Water tank...

Page 9: ...Pressure regulator 12 Pressure gauge 13 Supply hose holder 14 Pivot Locking Device 15 Supply hose reel lock 16 Water filter valve 17 HP pump 18 Hydraulic oil reservoir 19 Pulsator valve 20 Water tank...

Page 10: ...nction icon Pointer Engine LED Engine On button Navigator dial Vacuum LED Emergency stop Navigation bullets Tachometer High pressure spray LED High pressure spray button Vacuum button Key switch off m...

Page 11: ...Three Function eController The two figures below identify the Two Function and Three Function eController 2 FUNCTION ECONTROLLER The two function remote is identified by the two blue function indicat...

Page 12: ...each button will blink when the corresponding function is available The engine is ready to start or high pressure spray is available The Blue LED above each button will light solid when the correspond...

Page 13: ...The hose reel is actuated by rotating the Navigator dial clockwise to select down and counter clockwise to select up Depress the Navigator dial to select the action The speed of the hydraulic drive u...

Page 14: ...of two functions that can be selected by rotating the Navigator dial and activated by depressing the navigation knob Hose Counter allows the user to select on or off Counter Unit allows the user to s...

Page 15: ...g The Riomote radio remote control consists of a large waterproof and shockproof hand held sender and a unit mounted receiver The system is provided with separate batteries 8 hours per charge and is s...

Page 16: ...age tank to reduce pressure in the HP hose line PERSONAL PROTECTIVE EQUIPMENT The following personal protective equipment should be worn by personnel operating or working with the Urban Warrior Ear pr...

Page 17: ...aning with a spray gun Never block the controls in any way Put personal protective equipment on BEFORE you start the machine Ensure that the spray nozzle does not leave the drain SAFETY STICKERS 1 Saf...

Page 18: ...The mechanical relief in the unloader valve will prevent pressure from exceeding 3000 PSI WARNING If the unit fails to maintain pressure within the operating zone contact Spartan Tool Customer Service...

Page 19: ...tifreeze See page 25 Cold Weather Operation for more information 5 The vehicle is now ready for departure PLACEMENT OF URBAN WARRIOR 1 Put the vehicle at the desired location and set the parking brake...

Page 20: ...gency Stop can always be reached CAUTION Put on protective safety goggles and ear protection before starting the machine 2 Turn the key clockwise to position 1 Manual Control on Work Safe is displayed...

Page 21: ...38 39 5 Increase clockwise or decrease counter clockwise RPM by turning the Navigator dial 6 Depress the Navigator dial to display the Navigation Bullet menu Let the engine warm up After 3 minutes th...

Page 22: ...works its way through a drain line A clutch assembly 30 on the HP hose reel drive unit can be disengaged to allow the hose reel to free wheel for pulling the hose off the reel manually The hydraulic...

Page 23: ...sition Management 2 Depress the Navigator dial to activate the Management function The Navigation bullet extinguishes The Management underline illuminates 3 Once the Management function is activated t...

Page 24: ...the Riomote control on Press and hold the Start button on the Riomote to link the Riomote with the Urban Warrior Release the Start button when the blue corona stops blinking Corona illuminates contin...

Page 25: ...7 Depress the high pressure on button 35 Water begins spraying out of the nozzle at the end of the hose High pressure LED 33 lights blue High Pressure On is displayed on the eController screen for 2 s...

Page 26: ...he hose Ensure vehicles do not cross over the hose IMPORTANT Rewind hose onto reel under pressure to avoid crushing If machine has run out of water ensure hose is unwound before pressurizing COLD WEAT...

Page 27: ...the quick coupling tightly 4 Open the manual HP valve 7 5 Depress the High Pressure On button 6 Throttle up the engine speed by rotating the Navigator dial clockwise 7 Rotate the pressure regulator h...

Page 28: ...h pressure valve closes Pulsator valve closes if equipped Hose reel switches off 2 The operator can acknowledge the alarm display by depressing the Navigator dial in Manual Mode 3 Operation can only r...

Page 29: ...ates when low engine oil level is detected Engine stops High pressure valve closes Pulsator valve closes if equipped Hose reel switches off 2 The operator can override the alarm display by depressing...

Page 30: ...ng the Navigator dial in Manual Mode and continue operation 3 The High Pressure LED starts blinking when the run dry is active The override remains active as long as the Navigator dial is depressed SE...

Page 31: ...chnical Specifications Motor If oil level has dropped this implies a leak in the system In this case check all gaskets couplings and hydraulic hoses in the system Immediately repair damage and fill th...

Page 32: ...any pressure due to recirculation through the unloader valve If the spray gun is connected and closed the pressure gauge should NOT indicate any pressure due to recirculation through the unloader val...

Page 33: ...nit is on a level surface c Remove the dipstick A from the oil tank B d Clean the dipstick with a lint free rag e Put the dipstick back into the oil tank f Remove the dipstick and check the oil on the...

Page 34: ...rking hours or at least once every 6 months Lubricate moving parts Every 250 working hours or at least once every 6 months Clean pressure regulator Every 250 working hours or at least once every 6 mon...

Page 35: ...Hestia 46 Replace once a year Hydraulic oil tank capacity 5 liters Maximum hydraulic temperature 80 C Pressure regulator ULH 262 2H Year of construction See name plate on frame MOTOR Description Unit...

Page 36: ...nit Type Speck P52 Maximum pressure See name plate on frame Maximum output See name plate on frame Weight 120 lbs Maximum water temperature 60 C 140 F Gear oil GX 80W90 Gear oil capacity 118 fl oz Tec...

Page 37: ...Allow the machine to run a few minutes The failure will normally disappear If not contact Spartan Tool Customer Service Suction valves blocked Carefully loosen the valves and de scale them if necessa...

Page 38: ...tact points are dirty Check fuses Contact Spartan Tool Customer Service if problem is frequent or ongoing Transmitter is not on Activate the transmitter link to the receiver Transmitter out of reach f...

Page 39: ...ted the ECM has primary control of the engine providing prealarms alarms and safety shutdowns This attachment provides the operator with information necessary to understand the operation of the Engine...

Page 40: ...C Tel 013 5479100 e info r 12 5 This drawing is the property of Rior B V may not be reproduced without her con to third parties WWW RIONED COM 3 2 C VaultWorkspace Inventor 21 21255001000 iam Fold R i...

Page 41: ...9873500 Anti Turnaround Pipe Assembly 1 75729115 7 Channel Riomote Control 1 75729145 9 Channel Riomote Control 1 75729146 Riomote Battery Charger 1 75729116 Riomote Battery 1 75728000 Urban Series An...

Page 42: ...42 YOUR URBAN WARRIOR Unit Serial Number Engine Serial Number Pump Serial Number Notes...

Page 43: ...43 Notes...

Page 44: ...SINCE 1943 FOR TOUGH CUSTOMERS CONTACT US Spartan Tool LLC 1506 West Division Street Mendota IL 61342 800 435 3866 SpartanTool com 75720010MAN 1810...

Reviews: