SV Series
Spa Controls
14
Pump Operation
Keypad pump button assignments
IMPORTANT NOTE
In some configurations if heater is ON, activating multiple pumps may cause the heater to load shed and turn OFF, or reduce
element power (variable heater models). This is to keep the system within its maximum current limit. The heater will be re-
engaged or returned to full capacity as soon as the number of pumps running is reduced.
Pump Buttons
The jet pumps and/or filtration pump are controlled
via the pump buttons on the keypad. The functions
of the pump buttons change depending on pump
configuration, however Pump-A button is mostly
used to control the filtration pump.
The intention is to make best possible use of these
buttons for all possible pump configurations. For
every press of a pump button the display will
temporarily show the selected pump state:
ON / OFF / LOW / HIGH / AUTO
and then revert to the default display mode. The
most common pump configurations and button
assignments are referenced in the table aside.
IMPORTANT NOTES
•
In configurations where a pump button controls
the filtration pump and the heater is ON and pump
is to be turned OFF; the pump will turn OFF after a
5 second delay to allow the heater to cool down.
•
If left running, pumps will turn off after a 30
minute time out period. Time out period can be
adjusted from 10 to 60 minutes via the Setup
Menu item T.OUT (refer page 21).
•
If after manual spa use filtration pump is left OFF,
controller will revert to automatic mode 15
minutes after the expiry of the T.OUT period.