DPU/DO - Page 51 - REV. 5/25/00
POWER PRO PARAMETER SCREENS
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > R I G H T L I M I T S
* ( 0 ) S h a r e
( 1 ) D o n ' t S h a r e
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Right Limits Parameter Screen --
This parameter deals with how right limit switches are handled on an individual carriage. If the
carriage does not have its own right limit switch, but instead is using the limit switch on the left
side of the carriage to its right, this parameter should be set to SHARE. However, if this carriage
has its own right limit switch (and the carriage to its right has a left limit switch), this parameter
should be set to DON'T SHARE. This option might be used when the loaded weight of an
adjacent carriage is significantly different.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > P O W E R L I N E F R E Q U E N C Y
* ( 0 ) 6 0 H z
( 1 ) 5 0 H z
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Power Line Frequency Parameter Screen --
Operation of DC motor controls varies a great deal when the power line frequency changes. This
parameter screen allows the user to select the standard 60 Hz power line frequency, or the
European 50 Hz frequency for proper operation in some overseas installations.