DPU/DO - Page 43 - REV. 5/25/00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > M O V E F R O M S A F E T Y A C T I V A T I O N
* ( 0 ) N o
( 1 ) Y e s
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- EC300A Move From Safety Activation Parameter Screen --
In many cases it is desirable for a safety activation to access the aisle that is causing the
activation. By selecting YES from this parameter screen, the user sets the system to access the
affected aisle any time there is a sweep, aisle entry sensor or Zero Force Sensor activation.
Setting this parameter to NO disables this feature. For the EC400 this screen will not be
displayed because it does not support Move From Safety!
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > O P T R E G 4 - M O V E O N S A F E T Y
( 0 ) O p e n + S w e e p ( 2 ) S w e e p
( 1 ) O p e n + E n t r y ( 3 ) E n t r y / Z F S
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- EC300A Move on Safety Parameter Screen --
The system will open an aisle when a safety or aisle entry sensor is activated. The EC300A
software version 4.7 through 5.2 added a feature to prevent a completely closed aisle from
opening. The feature requires that the aisle be open enough for the far limit switch to be open
(approximately four inches). The four functions are listed below. For the EC400 this screen will
not be displayed because it does not support Move From Safety!
0 - Aisle must be open off the far limit switch and any safety activation.
1 - Aisle must be open off the far limit switch and an aisle entry or ZFS activation.
2 - Any safety activation will open the aisle.
3 - An aisle entry or ZFS activation will open the aisle.
Note: For the aisle entry to function separately from sweep, an adder board must be used and
plugged into hardware jumper J22 option 4 input.