background image

 

a

 

a

 

a.

 

Coat inside of agitators (if present) with 

Spaceman lubricant and install with arrow 

pointing up.

 

b.

 

Install internal and front drip trays.

 

c.

 

If machine will be left unused, install air 

tubes and place hopper lids on top; 

otherwise, set air tubes aside until after 

machine has been primed.

 

5. Install hopper cover, agitators, and drip trays

 

b

 

c

 

IMPORTANT: 

After sanitizing the machine, DO NOT rinse or touch areas that have been sanitized.  

Product must be added immediately. If new product will not be added immediately, rinse machine 

with clean water and loosen door hand

-

screws to allow cylinders to air

-

dry. Sanitize machine before 

using again.

 

1.

 

Verify assembly is complete.

 

2.

 

If installed, remove hopper covers and air 

tubes.

 

3.

 

Verify draw valves are in the CLOSED 

position (UP).

 

4.

 

Mix a minimum of 8 liters (2.11 gallons) of 

food

-

grade sanitizer in a bucket or 

container.

 

5.

 

Pour half the food

-

grade sanitizer solution 

into each hopper.

 

6.

 

Turn power switches ON.

 

7.

 

Press RESET button; press WASH button to 

begin cycle. Allow solution to agitate for 5 

to 10 minutes; 

NEVER leave machine on 

WASH for more than 10 minutes.

 

8.

 

While agitating, gently use a clean brush to 

scrub and distribute sanitizer solution along 

hopper walls.

 

9.

 

Place a bucket or container below the draw 

valves; OPEN the draw valves (DOWN) and 

drain solution from the machine.

 

10.

 

Press RESET buttons to stop cycle.

 

3

 

4

 

9

 

4

 

5

 

CAUTION: 

Always use food

-

grade, no

-

rinse sanitizer to sanitize. If warm water is required to dissolve 

sanitizer, allow the solution time to cool before adding to machine.

 

8

 

1

 

2

 

2

 

6

 

7

 

10

 

c

 

11

 

Preparation : 

Sanitize

 

Summary of Contents for 6210-C Series

Page 1: ...Soft Serve Models Two Line Display Standard or Air Pump Counter or Floor Standing ...

Page 2: ...SPM D XS TY001 R2 202005 ...

Page 3: ... that may lead to harm if protocol is not properly performed IMPORTANT Represents a vital mechanical step or note that the user must be aware of NOTE Non hazard but pay extra attention Green boxes throughout the manual represent instructions for machines with air pumps 1 Welcome to your Spaceman soft serve machine engineered to provide dependable operation and a consistent quality product Your mac...

Page 4: ... Remove plastic wrapping around machine 3 Cut stabilizing straps being careful not to scratch or dent the machine panels 4 Prepare the area where the machine will be placed remove packing cardboard from underneath machine and place ramp wedges near front casters 5 Unlock front casters and roll machine down the wedges off the pallet 6 Place the machine in its final location according to the Install...

Page 5: ...kets Side Middle Draw Valves with Seals Design Caps Prime Plug with Seals Screws Short Long Internal Drip Tray Front Drip Tray with Splash Shield Retention Pin with Nut Hopper Cover Tune Up Kit Quick Operation Guide Common Machine Parts Draw Handle Cleaning Guide Drive Shaft Gasket Beater Front Bearing Front Bearing Front Bearing 3 Getting to Know Your Machine Feed Tube V2 Gravity Feed Only Feed T...

Page 6: ...tion components and will void all warranties CAUTION The machine is designed to operate in normal ambient temperatures of 16o C to 24o C 60o F to 75o F Operating in higher ambient temperatures will result in degraded performance Power Connection L N G L1 L2 L3 G 1 Connect all wires to Circuit Breaker including neutral ground bus terminals or Local Plug according to supply voltage and wire codes on...

Page 7: ...r toxic chemicals and cleaners Doing so may cause damage to the stainless steel material ONLY use Spaceman included cleaning brushes and lubrication NEVER use metal objects to clean or operate the machine ALWAYS replace wearable parts a minimum of every 3 months ALWAYS prime machine prior to operating ALWAYS inspect parts for excess wear and damage NOTE Additional brushes lubrication wearable part...

Page 8: ...N Always separate O rings and gaskets from metal parts to prevent damage while washing b d a c c e a 1 Switch to OFF 3 Remove dispensing door a Remove dispensing door hand screws b Remove dispensing door assembly from cylinders 4 Disassemble dispensing door 2 If machine has air pumps disassemble them a OPEN draw handles to verify zero pressure in cylinders b Twist air tube connectors to unlock and...

Page 9: ...rive shaft b a d d c b 5 Disassemble beater assemblies Option A Stainless Steel Beater a Remove beater assembly from cylinder b Remove seal from beater assembly a b Option C Flexible Blade Beater V2 a Remove beater assembly from cylinder b Remove blades from beater assembly c Remove drive shafts from inside cylinder using a dry towel d Separate seal from drive shaft a b c 6 6 Remove internal drip ...

Page 10: ...ine using supplied brushes sponges and clean towels if machine has air pumps be sure to include all air pump parts in cleaning 6 When cleaning the dispensing door assembly clean the priming ports with a small brush 7 Carefully and thoroughly clean all gaskets and O rings removed from the machine be sure to wipe gaskets and O rings to remove excess lubricant 8 Verify all parts are clean prior to re...

Page 11: ...ssemblies until they engage the drive shaft keys and no longer turn 360 d f a 1 Switches to OFF c e a b 2 Install beater assemblies b Option C Flexible Blade Beater V2 a Install drive shaft seal lubricate drive shaft and end of seal Shaded Area b Insert drive shafts into rear shell bearings at the back of the cylinders and turn them until the key engages firmly into the socket when inserted correc...

Page 12: ...Place O rings on rear shells coating with Spaceman lubricant install gears into shells they only fit one direction b Connect covers and shells ensuring they fit flush secure with hand screws c Place O rings on suction tubes lightly lubricate O ring areas d Place air pump stoppers into air pump springs verifying orientation of stopper in spring insert into housings stopper first e Insert suction tu...

Page 13: ...ve hopper covers and air tubes 3 Verify draw valves are in the CLOSED position UP 4 Mix a minimum of 8 liters 2 11 gallons of food grade sanitizer in a bucket or container 5 Pour half the food grade sanitizer solution into each hopper 6 Turn power switches ON 7 Press RESET button press WASH button to begin cycle Allow solution to agitate for 5 to 10 minutes NEVER leave machine on WASH for more tha...

Page 14: ...uch Switch Panel To better communicate in the International arena symbols have replace words on many of your operator switches SPACEMAN equipment is designed with these international symbols 1 2 3 4 5 6 Turn on power Press and hold RESET for 3 seconds to enter into Menu Press RESET to turn to next page Machine Display Indicates Press RESET button to turn to STOP mode Press WASH button to turn to W...

Page 15: ...air tube at bottom 12 For machine with air pumps Insert air tube into hopper but do not connect to air pump Press RESET then press WASH to Prime Ensure product is coming out of the large hole near the top of the air pump Press RESET Rotate and insert air pump connector into air pump rotate connector to lock in place 13 Install hopper cover Product is now ready to freeze 1 6 2 7 8 3 4 NOTE The mix ...

Page 16: ...ET on Control Panel and re prime Lift up prime plug and make sure product comes out from bottom prime port Close prime plug 5 Press RESET then WASH button Once product comes out of two small holes on pump cover press RESET to complete priming 6 Observe machine performance and return to normal use if functioning properly Quick Freeze Dispense product 14 Machine power reset Turn on freezing immediat...

Page 17: ...rt draining after it completes in 3 to 5 minutes Nightly standby procedure Store closing 1 With machine in FREEZE mode remove air tubes 2 Clean air tubes hopper agitators design cap front trip tray and internal trip tray 3 Insert into machine upside down inlet hole on the side of the air tube at the top 4 Confirm product is above minimum product level top of hopper agitator blade in hoppers 5 Pres...

Page 18: ...emperature setting is too cold product will freeze around the sides of the hopper and potentially cause damage Hopper temperature should be set above freezing at 3 C to 4 C 37 F to 40 F 1 Press RESET to stop machine functions Press and hold RESET until display shows settings 2 Viscosity is the first setting shown press RESET again without holding temperature will be next If you scroll past the tem...

Page 19: ...cursor between fields Once highlighted a field can be changed 3 Press STANDBY to increase highlighted number Press P to decrease highlighted number 4 Press and hold ICE CREAM button for 3 seconds to save changes 1 Press RESET to stop machine functions Press and hold RESET until display shows settings 2 Press RESET to reach the Language setting If you scroll past the Language setting continue press...

Page 20: ... 5 3 5 6248 2 0 3 5 6350 1 8 2 8 6265 2 5 3 5 6265 2 0 3 5 6236 C 1 6 2 3 6268 2 5 3 5 6268 2 0 3 5 6338 C 1 6 2 3 6338 2 5 3 5 6338 2 0 3 5 6368 C 1 6 2 3 6368 2 5 3 5 6368 2 0 3 5 6378 C 1 6 2 3 6210 C 2 0 3 0 6210 C 2 0 3 0 6228 C 2 0 3 5 6228 C 2 0 3 5 220V 60Hz 3Ph 6236 C 2 0 3 5 6236 C 2 0 3 5 Model Viscosity Range A 6234 C 1 0 1 8 6234 C 1 0 1 6 6236 2 0 3 5 6235 C 2 0 3 5 6235 C 2 0 3 5 63...

Page 21: ... 31 2 2 3 4 08 01 013 O Ring 5 2x1 9 13 3 4 08 01 002 O Ring 18x2 2 3 3 4 08 01 006 O Ring 16 8x2 4 14 3 4 08 01 041 O Ring 71 8x3 4 3 4 08 02 007 Door Gasket SS 1 3 1 8qt 15 3 4 08 01 025 O Ring 15 8x2 4 5 3 4 08 02 008 Door Gasket SS 3 4qt 16 3 4 08 01 008 O Ring 11 5x2 5 6 3 4 08 01 011 O Ring 19x3 17 3 4 08 01 024 O Ring 13x1 5 7 3 4 08 01 019 H Ring 19x3x2 18 3 4 08 01 040 O Ring 11 2x1 4 8 3...

Page 22: ...5 14 4 3 6 9 15 16 17 18 13 12 1 2 O Rings Seals Scale 1 1 8 7 Use below 1 1 size comparison chart and explosion diagrams on left page to confirm item size and location of O rings and seals 20 20 ...

Page 23: ... t clogged allow machine 2 to 5 seconds between servings 5 G Clean air tube ensure proper orientation 6 A Check to make sure hand screws tight on pump shell body and that shell gasket is installed 7 Prime air pump 8 Turn on DEFROST mode Page 15 Probable Cause Malfunctioning power board Remedy Replace power board Problem STOP 3 Machine Protect Remedy 1 Install the dispensing door 2 Check and reinst...

Page 24: ...esn t have adequate ventilation 6 Viscosity adjustment is set incorrectly Remedy 1 Clean and properly lubricate machine daily 2 Ensure hopper is at least half full 3 Recycle fresh product 4 Follow manufacturer instructions for mixing product ensure correct mix ratios 5 Ensure at least 152mm 6 clearance on all sides 6 Raise viscosity setting as required Page 16 Probable Cause 1 Warm product was rec...

Reviews: