MAX
MIN
n m VA F M k
AUTO HOLD MAX MIN REL LOZ
0
10
20
30
40
MAX
MIN
n m VA F M k
AUTO HOLD MAX MIN REL LOZ
0
10
20
30
40
12
Operation cont.
1. Set the rotary function switch to the
position.
2. Press the
MODE
button until the
“
” symbol appears on the
display.
3. Insert the black test lead into the
COM
input jack and the red test
lead into the
Ω
input jack.
4. Touch the test lead probes to the
device or wire under test.
5. A beeper will sound if the resistance is approximately
50
Ω
or less and the resistance value will be shown
on the LCD display.
Continuity Measurements
Never test continuity
on a live circuit.
WARNING:
1. Set the rotary function switch to
the
position.
2. Press the
MODE
button until the
“
nF
” symbol appears on the display.
3. Insert the black test lead into the
COM
input jack and the red test
lead into the
Ω
input jack.
4. Touch the test lead probes to the
capacitor under test.
5. Read the capacitance value on
the LCD display. It may take up to a minute to get a
stable reading on large capacitors.
Capacitance Measurements
Safely discharge capacitors before
taking capacitance measurements.
WARNING:
MAX
MIN
n m VA F M k
AUTO HOLD MAX MIN REL LOZ
0
10
20
30
40
MAX
MIN
n m VA F M k
AUTO HOLD MAX MIN REL LOZ
0
10
20
30
40
MAX
MIN
n m VA F M k
AUTO HOLD MAX MIN REL LOZ
0
10
20
30
40
11
Operation cont.
1. Set the rotary function switch to the
position.
2. Press the
MODE
button until the
“
Ω
” symbol appears on the display.
3. Insert the black test lead into the
COM
input jack and the red test
lead into the
Ω
input jack.
4. Touch the test lead probes to the
component under test. If the
component is installed in a circuit,
it is best to disconnect one side before testing
to eliminate interference from other devices.
5. Read the resistance on the LCD display.
Resistance Measurements
Never test resistance
on a live circuit.
WARNING:
1. Set the rotary function switch to the
position.
2. Press the
MODE
button until the
“
” symbol appears on the display.
3. Insert the black test lead into the
COM
input jack and the red test
lead into the
Ω
input jack.
4. Touch the test lead probes to the
diode under test.
5. Forward voltage will indicate 0.4 to
0.7 on the display. Reverse voltage
will indicate “OL”. Shorted devices will indicate near 0
and an open device will indicate “OL” in both polarities.
Diode Test
Never test diodes
on a live circuit.
WARNING:
Red Black Black Red
Probe Probe Probe Probe
Forward test Reverse test
MAX
MIN
n m VA F M k
AUTO HOLD MAX MIN REL LOZ
0
10
20
30
40
MAX
MIN
n m VA F M k
AUTO HOLD MAX MIN REL LOZ
0
10
20
30
40