O
PERATION
S
TRATO
S
TEAM
EZ
C
OUNTERTOP
S
TEAMER
P
AGE
8
OF
56 O
WNER
’
S
M
ANUAL
1189953
(10/08)
S
HUTDOWN
Turn lever to the OFF position. The water in the bottom of the cavity will automatically drain.
T
ROUBLESHOOTING BY
O
PERATOR
The following table lists the possible causes and solutions of problems that may occur during operation.
Problem
Possible Causes and Solutions
Steamer does not heat up at all.
– Electric power is shut off. Turn on power.
– Not enough water is in steamer. Add water.
– Lime build-up. De-lime steamer cavity (see page 11).
– If water is OK and there is little lime build-up, call repair service.
Steamer does heat up, but does not produce enough steam.
– Door is open or ajar. Close steamer door completely.
– Steamer is in IDLE mode. Set Cook-Idle switch to COOK MODE
– Lime build-up. De-lime steamer cavity (see page 11).
– Not enough water. Add water.
Steamer does not drain correctly.
– Clogged drain on inside of steamer cavity. Check and clear.
– Clogged drain outside of steamer. Check and clear.