Figure 20
Pressure Switch Check
Continuity
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove right side cover.
3. Remove wires from pressure switch COM and NO terminals.
4. Open door of steamer.
5. Place test leads on COM and NO terminals, as shown above.
6. Check continuity. There should NOT be continuity. Replace as necessary.
7. Remove pressure switch.
8. With test leads on COM and NO terminals as before, gently blow into pressure port and check continuity.
There SHOULD be continuity. Replace as necessary.