Figure 6
Location of Connections and Vents
S
TEP
3:
W
ATER
C
ONNECTION
NOTICE
To meet warranty requirements, the supply water must meet the following specifications:
Pressure
30 to 60 PSI (205 to 410 kPa)
Total Dissolved Solids (TDS)
60 PPM or less
Hardness
2 grains (35 PPM) or less
pH
7.0 to 7.5
Chlorine and/or bromine
1 PPM or less
S
TEP
4:
E
LECTRICAL
C
ONNECTION
The electric connection is made to the contactor, which is located inside the service compartment on the right side of
the steamer. The right side panel must be removed to gain access to the contactor. A hole on the rear of each
steamer is provided for a 3/4" conduit fitting (solid or flex). An electric cable support bracket and clamp are located
inside of the service compartment, to the right and above the contactor (see Figure 7).
Be sure that the input voltage and number of phases matches the requirement stated on the serial plate. The steamer
is factory wired per customer order. A wiring diagram is attached to the inside of the right side panel of the steamer.
WARNING
A POSITIVE GROUND CONNECTION IS ESSENTIAL. DO NOT ALLOW ANY TAMPERING OR
ADJUSTMENT OF ANY CONTROL OR WIRING. THE STEAMER IS FACTORY SET. ADJUSTING ANY
INTERNAL COMPONENT CAN VOID THE WARRANTY.
THIS STEAMER REQUIRES A KIT TO BE FIELD CONVERTED FROM THREE-PHASE TO SINGLE-PHASE
OR VICE-VERSA. CONSULT FACTORY FOR PHASE CHANGES.
Summary of Contents for StratoSteam STRE-3EZ
Page 52: ...STRATOSTEAM EZ COUNTERTOP STEAMER PAGE 52 OF 56 OWNER S MANUAL 1189953 10 08 Notes ...
Page 53: ...STRATOSTEAM EZ COUNTERTOP STEAMER OWNER S MANUAL 1189953 10 08 PAGE 53 OF 56 Notes ...
Page 54: ...STRATOSTEAM EZ COUNTERTOP STEAMER PAGE 54 OF 56 OWNER S MANUAL 1189953 10 08 Notes ...
Page 55: ...STRATOSTEAM EZ COUNTERTOP STEAMER OWNER S MANUAL 1189953 10 08 PAGE 55 OF 56 Notes ...