ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED
TECHNICIAN WHO IS EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF
COMMERCIAL COOKING EQUIPMENT. HOWEVER, TO ASSURE YOUR CONFIDENCE,
CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR RELIABLE SERVICE, DEPENDABLE
ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY PARTS.
NOTICE
Warranty will be void and the manufacturer is relieved of all liability if service work is performed by
other than a qualified technician, or if other than genuine Southbend replacement parts are installed.
ACCESS TO SERVICEABLE COMPONENTS
To remove the top valve panel, first remove the knobs. Then remove the two screws on the bottom of the
valve panel. Pull the bottom of the valve panel away from the range. The top edge of the valve panel has
two small slots that hook over tabs on the frame.
LUBRICATION
The door chains and sprockets have been lubricated at the factory with high temperature “Never Seez”
lubricant. After each six months of usage, lubricate the door chains and sprockets with the same type of
lubricant.
Motor lubrication information can be found on permanent label located on motor.
Casters are provided with a fitting for proper lubrication when required.
ADJUSTING GAS PRESSURE REGULATOR
The pressure regulator is factory set at 6" (152mm) W.C. for natural gas and 10" (254mm) W.C. for
propane gas. To check the manifold pressure:
1. Turn the POWER switch to the OFF position.
2. Turn off main gas valve to entire unit.
3. Remove the upper valve panel and locate 1/8" (3mm) plug in manifold (see picture on next page).
4. Remove plug and install a fitting appropriate to connect a manometer.
5. Turn on main gas to unit and turn on POWER switch.
6. When the burners light, read manometer.
7. If manometer does not read 6" (152mm) W.C. for natural gas, or 10” (254mm) W.C. for propane gas,
adjust regulator (if gas pressure is correct, go to Step 10).
8. Remove cap from top of regulator.
9. With a screwdriver rotate regulator adjustment screw clockwise to increase, or counterclockwise to
decrease, pressure until manometer shows correct reading.
10. Turn the POWER switch to the OFF position, and turn off main gas valve to entire unit.