A
DJUSTMENTS
W
ENDY
’
S
G
AS
R
ANGE
P
AGE
24
O
WNER
’
S
M
ANUAL
1195747
A
D
J
U
S
T
M
E
N
T
S
11. Remove manometer fitting and replace plug in manifold.
12. Turn on main gas to unit, turn on POWER switch, and check that plug in manifold does not leak.
13. Replace upper valve panel.
CALIBRATION OF GAS GRIDDLE THERMOSTATS
Each 12" (305mm) section of the griddle is controlled by a snap-action type thermostat valve. If griddle
temperatures vary from the set point on the corresponding front-panel control, then calibration may be
needed. Use the following procedure to calibrate the griddle thermostats.
1. The griddle surface must be scraped clean. No product should be present on the griddle during
calibration.
2. Set all thermostats to 300°F (149°C) and allow them to cycle three to four times and allow the griddle to
preheat for 1 hour before proceeding.
3. Using a surface type thermometer placed at each Point “A” (as shown in the following diagram), check
the temperature for all of the thermostats by comparing the corresponding control setting to the
measured temperature. A tape measure should be used to verify the proper positioning of the
thermometer probe. If the temperature is not within 15°F (8°C), you need to adjust the thermostat
control.
Plug
Manifold Test Port