![South NTS-960R Operation Manual Download Page 212](http://html1.mh-extra.com/html/south/nts-960r/nts-960r_operation-manual_1336418212.webp)
205
Technical Specification
Distance
Measure
Part
Type
NTS
‐
962R
NTS
‐
965
R
Distance
Measurement
Max
distance
(Good
weather)
Single
prism
5.0Km
5.0Km
None
prism
300m
300m
Digisplay
Max
:
9999999.999
m
Min:1
mm
Precision
With
prism
:
2
+
2ppm
Without
prism
:
5
+
3ppm
Measure
time
Fine:2s
、
Quick
measure:1.2s
、
Track:0.6s
Atmospheric
correction
Auto
correction
Reflection
prism
correction
Auto
correction
Angle
Measurement
Measuring
method
Absolute
code
Raster
diameter
79mm
Min
display
unit
1”/
5”Selectable
Accuracy
2”
5”
Detection
method
Horizontal
:
Dual
Vertical
:
Dual
Telescope
Image
Erect
Tube
length
154mm
Effective
aperture
45mm
,
(EDM
:
50mm)
Magnification
30
×
Field
of
view
1
°
30’
Minimum
focusing
distance
1m
Resolving
power
3”
Auto
Compensator
System
Dual
axis
Liquid
‐
electric
Work
range
±
3’
Accuracy
1”
Vial