144
⑤
Rotate the telescope, making
“Turn” item and “
→
” item display
as 0, and ask the rodman to move
prism.
⑥
Sight the prism center, click
[Measure] to start measure. Ask the
rodman to move prism making
“Away” and “
↑
” display as 0.
⑦
When four items are 0, the point
to be set out is found. “Cut” item
indicates the dig/fil value.
When it is positive, it means to dig.
When it is minus, it means to fill.
⑧
After finish setting out one point,
click [Enter] to quit. The screen
returns to Alignment Setout main
screen.
Click [LOFS]/[ROFS]
,
or
+CHG/-CHG, repeat steps
②~⑥
to finish setting out other points.
※
1)
※
1) Press [LOFS] (or [ROFS]), corresponding chainage, offset, elevation difference will be displayed
on the screen. The chainage and offset can be entered manually. If the offset is minus, the offset point
is at the left side to center line.If the offset is positive, the offset point is at the right side to center line.
Explanation
for
the
main
setout
screen:
Summary of Contents for NTS-960R