189
Adjust
1.
Take
off
the
protective
cover
between
the
optical
plummet
eyepiece
and
focusing
knob.
2.
Fix
the
paper.
Rotate
the
instrument
and
mark
the
point
of
the
center
of
optical
plummet
which
falls
on
the
paper
at
every
90
°
.
As
illustrated:
Point
A,
B,
C,
and
D.
3.
Draw
lines
that
attach
AC
and
BD
and
mark
the
intersection
point
of
the
two
lines
as
O.
4.
Adjust
the
four
adjusting
screws
of
the
optical
plummet
with
an
adjusting
pin
until
the
center
mark
coincides
with
Point
O.
5.
Repeat
the
inspection
and
adjusting
steps
to
make
the
instrument
meets
the
requirements.
6.
Replace
the
protective
cover.
15.9 INSTRUMENT CONSTANT
(
K
)
Instrument
constant
has
been
checked
up
and
adjusted
in
the
factory,
K=0.
It
seldom
changes
and
it
is
suggested
to
check
one
or
two
times
every
year.
The
inspection
should
be
made
on
the
base
line,
also
can
be
made
according
to
the
following
method.
∙
Check
1.
Mount
and
level
the
instrument
on
Point
A
at
a
plain
field.
Use
the
vertical
hair
to
mark
Point
B
and
Point
C
with
the
distance
of
50m
on
the
same
line,
and
set
the
reflector
accurately.
2.
After
setting
temperature
and
air
pressure,
measure
the
horizontal
distance
of
AB
and
AC
accurately.
3.
Set
the
instrument
on
Point
B
and
center
it
accurately,
measure
the
Horizontal
Distance
of
BC
accurately.
4.
Then
the
Instrument
Constant
can
be
obtained:
K
=
AC
-
(AB
+
BC)
K
should
be
near
to
0,
If
|
K
|>
5mm,
the
instrument
should
be
strictly
inspected
in
the
standard
baseline
site,
and
adjusted
according
to
the
inspection
value.