BrewBlast™ 70CPH O&M
South-Tek Systems
9
Optional Mounting Bracket Kit Procedures
1.
All BrewBlast
™ BrewBlast™ 70CPH
mounting holes and optional mounting bracket holes are fo
r ¼”
screws/anchors.
2.
All brackets must be installed in orientation as shown to work correctly.
3.
Install the cabinet-mounting brackets on the BrewBlast
™ BrewBlast™ 70CPH
first with the provided
bolts/lock nuts.
4.
Locate the wall-
mounting bracket. It is an 18” bracket without the rectangular cutouts and will need to
be installed on the wall at the desired height and level. The bracket has 16” center to center holes so
the unit can be mounted directly to studs. This bracket will need to be mounted per the diagram below
using the appropriate hardware for your type of wall material (wood, sheet metal, masonry, etc.). The
12” bracket that is fastened to the top flange of the cabinet can be hung from the 18” bracket once the
18” bracket has been mounted to the wall. Reference the diagram below to see how the angles are to
be oriented on the back of the cabinet in comparison to the wall.
a.
Use the supplied nuts and bolts to attach the upper 12” bracket onto the top flange per the
diagram.
b.
Use the supplied carriage bolts and nuts to attach the 18” lower bracket to the bottom flange,
but do not overtighten the nuts yet. After installing the system, you may want to offset the
bracket slightly, hence the rectangular slots.
5.
Optional: I
f wall studs are not 16” center to center or you have the need to reinforce the mounting
area, a ½” or thicker plywood is recommended to be installed prior to hanging the system. Use best
general practices to ensure that the wood and system will be secure at its full weight and remember
that it will be vibrating from the compressor running.
6.
Once the mounting brackets are all in place, hang the BrewBlast
™ BrewBlast™ 70CPH
cabinet from
the top bracket making sure it is centered.
a.
The cabinet should have at least 4” on either side for breathing/cooling purposes.
b.
Do not install near heat source or where steam or water is present. Damage to system or
bodily harm may result as well as voiding warranty.
Warning: Secure the BrewBlast
™ BrewBlast™ 70CPH
to the wall at the top and bottom flanges. Failure to do so
could cause damage or bodily injury.
Summary of Contents for 70CPH
Page 4: ...BrewBlast 70CPH O M South Tek Systems 4 Notes...
Page 12: ...BrewBlast 70CPH O M South Tek Systems 12...
Page 13: ...BrewBlast 70CPH O M South Tek Systems 13 Optional Separate N2 Storage Tank Setup...
Page 19: ...BrewBlast 70CPH O M South Tek Systems 19...
Page 22: ...BrewBlast 70CPH O M South Tek Systems 22 Last Page...