The Bio Tuner Model BT6pro Manual

CHANGING THE CONDUCTIVE RUBBER ELECTRODES

1. Remove the Ear Clips from the Cord.
2. Gently pull the black Conductive Rubber Electrodes out of the Ear Clips.
3. Insert the new Conductive Rubber Electrodes into the Ear Clips. Press the 

Electrode into place.

OUTPUT OF SIX MODES 

The Bio Tuner provides six different Modes with which to experiment and discover 

what feels or works best. Try different Modes to determine which feels most 

comfortable. With extended use, it is recommended to vary the Mode from time to 

time, as your body can become acclimatized. 

One Mode is not considered more beneficial than another. 

In all Modes, the base frequency of 1,000 Hz pulse-modulated by 111.11 Hz is present. 

Modes 4, 5, and 6 may have a more gentle feel.

BIO TUNER MODES

MODE 1-3 (550 uS pulse width)

Mode 1: 1,000 Hz modulated by 111.11 Hz, 

Output = Continuous
Mode 2: 1,000 Hz modulated by 111.11 Hz, 

Output = 1 Second ON, 1 Second OFF (0.5 Hz)
Mode 3: 1,000 Hz modulated by 111.11 Hz,   

Output = Amplitude Modulated  by 7.83 Hz Schumann (Earth) Sine Wave

MODE 4-6 (220 uS PULSE WIDTH) 

Mode 4: 1,000 Hz modulated by 111.11 Hz,   

Output = Continuous
Mode 5: 1,000 Hz modulated by 111.11 Hz,   

Output = 1 Second ON, 1 Second OFF (0.5 Hz)
Mode 6: 1,000 Hz modulated by 111.11 Hz,   

Output = Amplitude Modulated by 7.83 Hz Schumann (Earth) Sine Wave 

Summary of Contents for BT6pro

Page 1: ...CAUTIONS 3 SUMMARY OF LIGHTS 4 HOW TO USE THE BIO TUNER 4 Headset Option 4 Conductive Pads Option 4 Ear Clips Option 5 Turning the Unit On 5 How it Should Feel 6 Typical Use 7 Changing the Conductive...

Page 2: ...pendently but can also be used together with any of the SOTA Products With proper care your Bio Tuner should provide you many years of trouble free use Please understand that results will vary BEFORE...

Page 3: ...l to ensure safety CAUTIONS 1 If you are on psychiatric medication have a neurological condition or seizures please consult your health care provider prior to using the Bio Tuner 2 In very rare instan...

Page 4: ...e battery terminals c Slide the 9 Volt Alkaline battery into the case and push down d Slide the cover back onto the unit HEADSET OPTION 2 Clean the area behind each ear to eliminate skin oils This wil...

Page 5: ...begin to flash alternately once every second indicating the unit is in Mode 1 If the lights do not come on the battery may not be properly connected 4 Gradually turn up the intensity to a comfortable...

Page 6: ...h the use of either conductive gel or aloe vera gel rather than water Over time the Ear Clips may lose their conductivity and will need to be replaced Changing Modes When the Mode is changed during a...

Page 7: ...s per session the benefits may be reduced The unit can be used for up to three 40 minute sessions per day space the sessions throughout the day Length of Use The unit should be used daily at least 2 s...

Page 8: ...om time to time as your body can become acclimatized One Mode is not considered more beneficial than another In all Modes the base frequency of 1 000 Hz pulse modulated by 111 11 Hz is present Modes 4...

Page 9: ...you to ensure the batteries will fit the enclosure OUTPUT SPECIFICATIONS Maximum 1 5mA Peak 40 Volts Peak Peak into typical 4k ohm load Minimum 10uA 10 Volt Peak Peak at lowest setting Output impedanc...

Reviews: