19
XTL-W7000
SECTION 4
TEST MODE
Note:
To perform the Test Mode, remote commander (RM-X701) is
requisite.
1. ENTERING THE TEST MODE
Procedure:
1. Apply the voltage of 14.4 V to the ACC and BACKUP cord.
2. While pressing the
[CUSTOM]
button, press the
[RESET]
button. (Hold the
[CUSTOM]
button press)
3. Release the
[RESET]
button and after two seconds, release the
[CUSTOM]
button.
4. Press the
[OPEN/CLOSE]
button to open the monitor and
display as following figure (top menu).
5. From the top menu screen, press the
[1]
button on the remote
commander to display as following figure (ENGINEER menu).
6. To back to the top menu screen, press the
[BACK]
button on
the remote commander.
Note:
The items of “2. FACTORY MEASURE” and “3. FACTORY
CHECK” in the top menu are not used in servicing.
2. RELEASING THE TEST MODE
Procedure 1:
Press the
[OFF]
button on the remote commander to setting data is
saved.
Procedure 2:
Press the
[RESET]
button: Setting data is not saved.
3. OPERATION OF EACH ITEMS
This mode is used in order to perform adjustment in connection
with the whole set.
3-1. SYSTEM Mode
1. In the ENGINEER menu screen, press the
[1]
button on the
remote commander to enter the SYSTEM mode and display
as following figure.
2. Press the
V
/
v
button on the remote commander to select
the item. And press the
[VOL ---]
/
[VOL +]
button to change
the value.
3. If initialize all values, select the “SYSTEM INIT” and press
the
[ENTER]
button on the remote commander.
4. To save the data and release the Test Mode, press the
[BACK]
button and press the
[OFF]
button on the remote commander
Item in the SYSTEM Mode:
Item
Contents
SYSTEM INT
Initialize the preset data, PAL system and security
code
PAR
PARKING terminal setting
ON : Parking position
OFF : Release the parking position
REV
REVERSE terminal setting
ON : Reverse position
OFF : Release the reverse position
ILL
ILLUMINATION terminal setting
ON : Illumination on
OFF : Illumination off
ATT
Not used
N/P
Judgment value setting of NTSC/PAL
DIML
DIMMER LOW level setting (000 to 255)
Initial value: 61 (no change)
DIMM
DIMMER MID level setting (000 to 255)
Initial value: 51 (no change)
DIMH
DIMMER HIGH level setting (000 to 255)
Initial value: 40 (no change)
3-2. TV Mode
Not used in servicing.
TEST
1 ENGINEER
2 FACTORY MEASURE
3 FACTORY CHECK
SYS VERx.x.xx OSDVERx.x.xx
TEST
1 SYSTEM
2 TV
3 MECHA
4 MONITOR1
5 MONITOR2
6 MONITOR3
7 MONITOR INIT
8 DIMMER INIT
TEST SYSTEM
SYSTEM INIT
PAR ON ATT *** DIML 61
REV OFF N/T 10V DIMM 51
ILL OFF DIMH 40