69
FTP File Operations
A
ppe
ndix
Input example:
SITE REPF FILE00000010.MXF 50 200 4 0
This transfers FILE00000010.MXF. The body consists
of 200 frames starting from frame 50, audio consists of
CH 1 to 4, and a metadata packet will not be added.
SITE MEID
Obtains the ID of a memory card inserted in this unit.
Command syntax: SITE MEID <SP> <memory card slot
number> <CRLF>
Input example:
SITE MEID SRMemoryCard1
Network Interface Settings
IP addresses and other settings related to the network are
configured in the NETWORK SETUP menu of the
maintenance menu. This section provides a simple
overview. For details, see the Maintenance Manual.
To change the settings in the NETWORK SETUP
menu
1
While a normal menu (e.g., HOME) is displayed, press
the DIAG button while holding down the SFT button.
The MAINTENANCE INFORMATION menu
appears.
2
Press the
[F8]
(MAINTENANCE),
[F9]
(OTHERS
CHECK), and then
[F3]
(NETWORK SETUP)
buttons.
The menu display changes with each button, and the
NETWORK SETUP menu appears.
The current setting configurations appear on the menu
screen.
3
Press the parameter button of the setting you want to
change.
[F1]
(NETWORK1 IP ADRS) IP address of Network 1
[F2]
(NETWORK1 SUBNET): Subnet mask of
Network 1
[F3]
(NETWORK2 IP ADRS): IP address of Network
2
[F4]
(NETWORK2 SUBNET): Subnet mask of
Network 2
[F5]
(NET1/2 GATEWAY): Default gateway of
Networks 1 and 2
[F6]
(10G NETWORK IP ADRS): IP address of
optional 10Gbit network
[F7]
(10G NETWORK SUBNET): Subnet mask of
optional 10Gbit network
[F8]
(10G NETWORK GATEWAY): Default
gateway of optional 10Gbit network
[F9]
(10G NETWORK MTU): MTU of optional
10Gbit network
4
Change the settings.
If you pressed
[F1]
to
[F8]
in step
3
:
The display for the selected setting turns orange. Use
the numeric buttons to enter a value.
To move the cursor, use the left and right cursor
buttons (
<
/
,
).
To confirm the setting, press the SET button and verify
that the value display turns white.
If you pressed
[F9]
in step
3
:
The background of the value display for the
[F9]
button turns orange. Use the up and down cursor
buttons (
M
/
m
) or the MULTI CONTROL knob to
change the value.
To confirm the setting, press the SET button and verify
that the value display turns to normal.
5
Press the
[F10]
(EXIT) button three times.
The MAINTENANCE INFORMATION menu
appears.
6
Press the button for a normal menu such as HOME to