MODE SELECT
6.Command Specification
SONY AIT-5 drive SDX-1100V series Ver.1.0
6-43
Supported page codes are:
Table 6-42: Supported MODE SELECT Page Codes
Page Code
Description
00h
02h
0Ah
0Fh
10h
11h
1Ch
31h
32h
33h
3Fh
Standard Sense
Disconnect-Reconnect
Control Mode Page
Data Compression Control
Device Configuration
Medium Partitions Parameter
Information Exception Control
AIT Device Configuration
Append Partition (obsolete)
Delete Partition (obsolete)
Return All Pages
Additional Page Length:
Indicates the number of bytes in that page. The value does not, however, include bytes
0 and 1. The length is returned on MODE SENSE and must subsequently be set to the same value when
performing MODE SELECT.
If the page length does not match that expected by the drive a CHECK CONDITION status is returned with the
sense key to set to ILLEGAL REQUEST.
The drive also returns a CHECK CONDITION status with an ILLEGAL REQUEST sense key if the initiator sends
an unsupported Page Code, a page field with values that are not supported or are not changeable. In this case, no
parameters will have been changed by the command.