6.Command Specification
LOG SENSE
6-22
SONY AIT-5 drive SDX-1100V series Ver.1.0
Code
Flag
Flag Type
Recommended application client message
Probable cause
1Eh
Hardware A
C
The tape drive has a hardware fault:
1. Eject the tape or magazine.
2. Reset the drive.
3. Restart the operation.
The drive has a hardware
fault that requires reset to
recover.
1Fh
Hardware B
C
The tape drive has a hardware fault:
1. Turn the tape drive off and then on again.
2. Restart the operation.
3. If the problem persists, call the tape drive
supplier helpline.
Check the tape drive user’s manual for device
specific instructions on turning the device power
on and off.
The drive has a hardware
fault which is not read/write
related or requires a power
cycle to recover.
20h
Interface
W
The tape drive has a problem with the initiator
interface:
1. Check the cables and cable connections.
2. Restart the operation.
The drive has identified an
interfacing fault
21h
Eject Media
C
The operation has failed:
1. Eject the tape or magazine.
2. Insert the tape or magazine again.
3. Restart the operation.
Error recovery action
22h
Download Fail
W
The firmware download has failed because you
have tried to use the incorrect firmware for this
tape drive.
Obtain the correct firmware and try again.
Firmware download failed
23h Drive
Humidity
W Environmental conditions inside the tape drive
are outside the specified humidity range
Drive humidity limits
exceeded
24h Drive
Temperature
W
Environmental conditions inside the tape drive
are outside the specified temperature range
Drive temperature limits
exceeded
25h Drive
Voltage
W The voltage supply to the tape drive is outside
the specified range
Drive voltage limits exceeded
26h Predictive
Failure
C
A hardware failure of the tape drive is predicted.
Call the tape drive supplier helpline.
Predictive failure of drive
hardware
27h Diagnostics
Required
W
The tape drive may have a fault. Check for
availability of diagnostic information and run
extended diagnostics if applicable.
Check the tape drive users manual for
instructions on running extended diagnostic
tests and retrieving diagnostic data
The drive may have had a
failure which may be
identified by stored
diagnostic information or by
running extended
diagnostics (e.g. Send
Diagnostic)
28h Loader
Hardware A
C
The changer mechanism is having difficulty
communicating with the tape drive:
1. Turn the autoloader off then on.
2. Restart the operation.
3. If problem persists, call the tape drive supplier
helpline.
Loader mechanism is having
trouble communicating with
the tape drive
29h Loader
Stray
Tape
C
A tape has been left in the autoloader by a
previous hardware fault:
1. Insert an empty magazine to clear the fault.
2. If the fault does not clear, turn the autoloader
off and then on again.
3. If the problem persists, call the tape drive
supplier helpline.
Stray tape left in loader after
previous error recovery
2Ah Loader
Hardware B
W
There is a problem with the autoloader
mechanism.
Loader mechanism has a
hardware fault