LOG SENSE
6.Command Specification
SONY AIT-5 drive SDX-1100V series Ver.1.0
6-33
6.6.13.
MIC Fixed Length Information Page (3Dh) (Sony Unique)
Table 6-36: MIC Fixed Length Information Page
Bit
Byte
7 6 5 4 3 2 1 0
0
Page Code (3Dh)
1
Reserved
2
(MSB)
Page Length (n+1)
3
(LSB)
Parameter Code:
Code Description Length
0001h
MIC Logical Format Type
4
0002h
Device Configuration bits
4
0003h
Available free byte count
4
0004h
User Volume Note size
4
0005h Reserved
8
0006h
Cassette Serial Number, etc.
32
0007h Reserved
32
0008h Reserved
32
0009h Reserved
32
000Ah Reserved
32
000Bh Reserved
32
000Ch Reserved
32
000Dh Reserved
32
000Eh Reserved
32
000Fh Reserved
32
0010h Reserved
32
0011h Reserved
32
0012h Reserved
32
0013h Reserved
32
0014h Obsolete
32
0015h
Accumulative System Log
90
0016h Volume
Information
96
0017h Element
Address
96
0018h
User Partition Note size for Partition #0
4
Note:
1.
Parameter Code 0002h AIT Device Configuration Byte is the same byte value returned in Mode Sense Page
31h byte 2. See page 6-58 paragraph 6.8.1 for a description of the fields in this byte.
2.
Parameter Code 0003h Available Free Byte Count represents the current user MIC memory that is available
for writing data to the MIC using the Log Select command through Page 3Eh Parameter Code 0001h,
0002h, …. 000Nh. If Available Free Byte Count is 1 or higher the application may use exactly that size or
smaller to write MIC User data. If this field is ZERO a Check Condition status is returned if attempts are
made to write data to the MIC. If the application attempts to write data to the MIC that is larger than this field
a Check Condition status will also be returned. In both cases where Check Condition status is returned no
data is written to the MIC.