2.Specification
SONY AIT-5 drive SDX-1100V series Ver.1.0 2-5
2.2.2.
Altitude
Operating
0 to 10,000 feet
2.2.3.
Suspended Particulate
Operating
Less than 150 microgram/m
3
Based Sampling period 24 hours
2.2.4.
Vibration
Operating
Swept Sine 5 to 500Hz, @0.25G Peak 1 Octave/min.
3 axis, 3 directions
Non-operating
Swept Sine 5 to 500Hz, @ 0.5G Peak 1 Octave/min.
3 axis, 3 directions
2.2.5.
Shock
Operating
No Data Loss
Half Sine
Performance
5 G Peak 3 ms
3 axes, 3 directions
*Interval 10 seconds
Non-operating
No Device Damage
Half Sine
90 G Peak 3 ms
(30 G Peak 11 ms)
3 axes, 3 directions
*Interval 10 seconds
2.2.6.
Acoustic Noise
The ambient noise level is no greater than 25 dB (A). The sound-meter on (A) scale is located 1m in front of the
center of the drive front panel. (A): A curve weight
Streaming Write/Read
35dB(A)
Insert/Eject 60dB(A)
2.2.7.
EMC
EMI/EMS
Radiated Emissions /
Conducted noise
Emissions
EN 55022 / 94 + EN 55022 A1 / 95 class B
EMS ESD
(Front Panel Only,
integrated product)
Discharge Voltage
Less than 15kV: No operation failure
Less than 20kV: No drive damage
2.2.8.
Orientation
The SDX-1100V can be installed in three different mounting positions as shown in the figure below. Each position
has a maximum tolerance of ± 10 degrees.