Error/Warning Indications
101
Ap
pend
ic
es
The camcorder informs you of situations where warning, caution, or an operation check is required,
through messages on the viewfinder screen, the recording/tally lamp, and a buzzer.
The buzzer is output to the built-in speaker or to the headphones connected via the headphone connector.
The camcorder stops operation after the following indications.
When one of the following indications is generated, follow the message to resolve the problem.
Error/Warning Indications
Error Indications
Error indication on
LCD/viewfinder
Buzzer
Recording/
tally lamp
Cause and measures
E + Error code
Continuous
Rapidly
flashing
The camcorder may be defective. Recording stops even if
z
Rec is displayed on the viewfinder screen.
Turn off the power and check the connected equipment, cables,
and media. If they are not defective, turn on the power again. If
the error persists, consult Sony service personnel.
(If power cannot be turned off by setting the ON/STANDBY
switch to STANDBY, remove the battery pack and/or the DC
IN source.)
Warning Indications
Warning indication
on LCD/viewfinder
Buzzer
Recording/
tally lamp
Cause and measures
Media Near Full
Intermittent
Flashing
Free space on the SxS memory card has become insufficient.
Replace it with another at the earliest opportunity.
Media Full
Continuous
Rapidly
flashing
No space is left on the SxS memory card. Recording, clip
copying and clip division cannot be performed.
Replace it with another.
Battery Near End
Intermittent
Flashing
The battery power will be discharged soon.
Charge the battery pack at the earliest opportunity.
Battery End
Continuous
Rapidly
flashing
The battery pack is discharged. Recording cannot be
performed.
Stop operation and change the battery pack.
Temperature High
Intermittent
Flashing
The internal temperature has risen above a safe operation
limit.
Suspend operation, turn off the power, and wait until the
temperature falls.
Voltage Low
Intermittent
Flashing
The DC IN voltage has become low (stage 1).
Check the power supply.
Insufficient Voltage
Continuous
Rapidly
flashing
The DC IN voltage is too low (stage 2). Recording cannot be
performed.
Connect another power source.
Summary of Contents for PXW-X160
Page 118: ...Index 118 Appendices ...
Page 119: ...Index 119 Appendices ...
Page 120: ...Printed in China ...