2.
Remove the two precision screws (M2 x 5) to detach the control panel assembly.
Precision screws
(M2 x 5)
Precision screws
(M2 x 5)
Control panel assembly
Hinge (front) cover assembly
3.
Remove the shoe spring.
4.
Remove the four precision screws (M2 x 6) to detach the accessory shoe.
5.
Remove the precision screw (M2 x 5) to detach the MIC cabinet assembly.
Precision screws
(M2 x 6)
Precision screw
(M2 x 5)
MIC cabinet assembly
Accessory shoe
Shoe spring
6.
Disconnect the flexible board from the connector CN100 on the KSW-62 board.
7.
Remove the precision screw (M2 x 4) to detach the FP-179 board.
8.
Remove the two tapping screws (2 x 5) to detach the MIC case.