5-38E
9. Self Diagnosis Log check
Page 2
Address B3 to B5
Example:
C : 32 : 01
Address : B5
Address : B4
Address : B3 (Note)
Note:
“C”
→
“01”
“E”
→
“03”
Using method:
1)
The self diagnosis log is displayed at page: 2, addresses: B3 to B5.
Note1:
When no error occurs in this unit, data “00” is written in addresses B3 to B5.
When the last error occurs, the data corresponding to the error is written in the address (B3 to B5).
Note2:
These data will be erased when the coin lithium battery (JK-208 board BT101) is removed (reset).
Address
B3
B4
B5
Function
Last error occurrence code
Initial value
00
00
00
10. Record of Use check
Page D
Address EC to EF
Using method:
1)
The recording counter data is displayed at page: D, addresses: EE to EF. These data are named D
EE
and D
EF
respectively.
2)
Convert D
EE
and D
EF
to decimal notation, and obtain D
EE
’ and D
EF
’.
(Refer to Table 5-2-1. “Hexadecimal-decimal conversion table”.)
3)
Calculate the recording counter (N) using following equation. (Decimal calculation)
N = D
EF
’ + D
EE
’
×
256
Initializing method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: EC to EF, and write data: 00 to each address.
Note:
Press the PAUSE button of the adjustment remote commander each time to set the data.
3)
Select page: 0, address: 01, and set data: 00.
Address
EC
ED
EE
EF
Function
Recording counter
(Hexadecimal)
Remarks
Not used.
1000-digit and 100-digit
10-digit and 1-digit