1-25(E)
JME-SA200
48
Adjustment
Displaying the Software Version of the JME-SA200
You can display the version of the software installed in this controller in
the display window.
1
Establish communication with the ICU controller (page 21) and
display the MAIN MENU.
2
Press the
v
or
V
button to select OTHER CONTROL and press the
ENTER button.
The OTHER CONTROL menu appears.
S W I T C H E R C O N T R O L
S I G N A L C O N T R O L
G E O M E T R Y C O N T R O L
M O N I T O R C O N T R O L
S C R E E N C O N T R O L
S C R E E N U N I T C O N T R O L
O T H E R C O N T R O L
* * * * * * M A I N M E N U * * * * * *
S C R E E N I N F O
P R O D U C T I N F O
* * * * O T H E R C O N T R O L * * * *
3
Press the
v
or
V
button to select PRODUCT INFO and press ENTER
button.
The information about the software version appears in the display
window.
N a m e - - - - - - - S A 2 0 0
V e r s i o n - - - - 1 . 0 0
s a 2 0 0 s y s - 1 . 0 0
s a 2 0 0 k b d - 1 . 0 0
s a 2 0 0 d s p - 1 . 0 0
s a 2 0 0 r x - 1 . 0 0
s a 2 0 0 t x - 1 . 0 0
s a 2 0 0 u s r - 1 . 0 0
s a 2 0 0 r x p - 1 . 0 0
s a 2 0 0 t x p - 1 . 0 0
* * * *
P R O D U C T I N F O * * * *
To stop displaying the information
Press the MENU button.
Others
49
Remove the cause of the problem, turn the power on and
establish communcation again. Perform the adjustment from
the stage in which you have pressed the ENTER button.
Check the cellular phone connections.
The cellular phone is not
connected to the unit properly.
(for wireless control)
The battery for the cellular phone
is exhaused.
The menu or the data on
the display does not
change even if the button
is pressed. (for wireless
control)
Check the connections.
The battery pack is not attached
to the unit.
Troubleshooting
If you think you have a problem during operation, check through the
following list.
The title display does not
appear after the power has
been turned on and four
seconds or more have
elapsed.
Problem
Corrective action
Attach the battery pack.
The battery is exhaused
completely.
Cause
Charge the battery.
The MAIN MENU does not
appear in the display
window.
The unit is not connected to the
ICU controller properly. (for wired
control)
The digital data card is not
inserted correctly. (for wireless
control)
Insert the card fully into the slot.
The phone number for the modem
has not been registered.
The cellular phone is not
connected to the unit properly.
The communication has
interrupted.
Summary of Contents for JumboTron JME-SA200
Page 1: ...SERVICE MANUAL MODEL DEST JME SA200 World SCREEN ALIGNMENT CONTROLLER ...
Page 3: ......
Page 36: ......
Page 38: ......
Page 40: ......
Page 46: ......
Page 48: ...8 2 8 2 JME SA200 SAK SAK A SIDE SUFFIX 11 SAK B SIDE SUFFIX 11 ...
Page 50: ...8 4 8 4 JME SA200 SAP SAP SAP A SIDE SUFFIX 11 SAP B SIDE SUFFIX 11 ...
Page 53: ...8 7 8 7 JME SA200 SAC SAC SAC B SIDE SUFFIX 11 ...
Page 57: ......