1-18(E)
JME-SA200
34
Adjustment
Checking the Screen Display Unit
You can display the test patterns automatically and repeatedly on a
specified screen display unit to check if the unit is operating properly.
This function is useful when checking on the cause of a malfunction of the
unit, or after adjusting, repairing or replacing the unit.
1
Establish communication with the ICU controller (page 21) and
display the MAIN MENU.
2
Press the
v
or
V
button to select SCREEN UNIT CONTROL and press
the ENTER button.
The SCREEN UNIT CONTROL menu appears.
S W I T C H E R C O N T R O L
S I G N A L C O N T R O L
G E O M E T R Y C O N T R O L
M O N I T O R C O N T R O L
S C R E E N C O N T R O L
S C R E E N U N I T C O N T R O L
O T H E R C O N T R O L
* * * * * * M A I N M E N U * * * * * *
* SCREEN
UNIT CONTROL
*
CHECK
ADJUST
REGIST
RECALL
3
Press the
v
or
V
button to select CHECK and press the ENTER button.
The SCREEN UNIT/CHECK menu appears.
* S C R E E N U N I T
/
C H E C K *
M O D E : T E S T
U N I T N U M B E R
X : 1 Y : 1
S C R E E N N U M B E R : 1
4
If two or more screens are installed, select the screen number.
Press the
v
or
V
button to select SCREEN NUMBER and press the
B
or
b
button to change the number.
* S C R E E N U N I T
/
C H E C K *
M O D E : T E S T
U N I T N U M B E R
X : 1 Y : 1
S C R E E N N U M B E R :
1
Note
If only one screen is installed, do not change SCREEN NUMBER from 1.
If a number other than 1 is set, the test pattern cannot be displayed even if
you assign the unit number correctly.
Screen number
Adjustment
35
5
Assign the unit number.
Press the
v
or
V
button to select X or Y of UNIT NUMBER and press
the
B
or
b
button to change the number.
By pressing the
v
button, X and Y are selected in order. By pressing
the
V
button, they are selected in the reverse order.
* S C R E E N U N I T
/
C H E C K *
M O D E : T E S T
U N I T N U M B E R
X :
3
Y : 1
S C R E E N N U M B E R : 1
6
Press the ENTER button.
The test pattern is displayed on the assigned unit. The stair step and
color bars (and beam blanking for the CRT type unit only) change
automatically on the unit. Check if the unit is operating properly.
Test pattern
Operating and circuit to be checked
Stair step (data of the same bit)
Bit errors, etc
Color bars
Data latch timing, etc.
Beam blanking
Cathode switching circuit, etc. (CRT
(switching the blanking line)
type unit only)
To stop the test pattern display
Press the MENU button. The display window returns to the MAIN
MENU.
Counting the unit number
The top-left unit on the screen is counted as number 1 for either horizontal
(X) or vertical (Y) direction.
X: Unit number in horizontal direction
Y: Unit number in vertical direction
1
1
2
3
4
2
3
Example: Unit number
X: 3 Y: 4
X
Y
Summary of Contents for JumboTron JME-SA200
Page 1: ...SERVICE MANUAL MODEL DEST JME SA200 World SCREEN ALIGNMENT CONTROLLER ...
Page 3: ......
Page 36: ......
Page 38: ......
Page 40: ......
Page 46: ......
Page 48: ...8 2 8 2 JME SA200 SAK SAK A SIDE SUFFIX 11 SAK B SIDE SUFFIX 11 ...
Page 50: ...8 4 8 4 JME SA200 SAP SAP SAP A SIDE SUFFIX 11 SAP B SIDE SUFFIX 11 ...
Page 53: ...8 7 8 7 JME SA200 SAC SAC SAC B SIDE SUFFIX 11 ...
Page 57: ......