6-126
HVR-Z7J/Z7U/Z7N/Z7E/Z7P/Z7C
3-3.
SERVO AND RF SYSTEM ADJUSTMENTS
Before perform the servo and RF system adjustments, check that
the specified values of “Origin Oscillation check” of “1-3. CAM-
ERA SYSTEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”. If not, select
page: 0, address: 10, and set the data “00”.
Adjusting Procedure:
1. CAP FG duty adjustment
2. Switching position adjustment
3. Error rate check
1.
CAP FG Duty Adjustment (TT-007 board)
RadarW
RadarW
RadarW
Set the CAP FG signal duty cycle to 50% to establish an appropri-
ate capstan servo. If deviated, the uneven rotation of capstan and
noise can occur.
Mode
VTR stop (VCR mode)
Signal
No signal
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
16
Specified value
The data of page: 3, address: 03 is
“00”
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compart-
ment without inserting
cassette.
2
0
01
01
3
3
71
01
Press PAUSE (Write) button.
4
3
03
FF
5
C
16
20
Press PAUSE (Write) button.
6
3
01
1B
Press PAUSE (Write) button.
7
3
02
Check the data changes in
the following order
“1B”
t
“2B”
t
“00”
8
3
03
Check the data is “00”. (Note 2)
9
3
01
00
Press PAUSE (Write) button.
10
3
70
10
Press PAUSE (Write) button.
11
3
70
Check the data changes to
“11”.
12
0
01
00
Note 2:
If the data is “01”, adjustment has errors or the mecha-
nism deck is defective.
If the data is “80”, the mechanism deck is in emergency
state or the end of tape was detected.