6-45
HVR-Z7J/Z7U/Z7N/Z7E/Z7P/Z7C
11. LV Standard Data Input
RadarW
RadarW
RadarW
Adjust the normal coefficient of the light value at 3200K.
Adjustment Page
6D
Adjustment Address
5C, 5D
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: D (6D), address: 5C and 5D.
Note:
Press the PAUSE (Write) button of the adjustment remote com-
mander each time to set data.
Address
Data
5C
36
5D
10
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
12. STD GAIN Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Correct a variation in the CMOS sensitivity setting.
As the CMOS sensitivity is dominant on the variation, correct it
with the AGC_GAIN standard setting.
Adjustment Page
6D
Adjustment Address
5A, 5E, 5F
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: D (6D), address: 5A, 5E and
5F.
Note:
Press the PAUSE (Write) button of the adjustment remote com-
mander each time to set data.
Address
Data
5A
00
5E
0B
5F
86
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.