6-27
HVR-Z7J/Z7U/Z7N/Z7E/Z7P/Z7C
3.
ND Filter Switch Adjustment
Adjust a variation in AD value of the ND filter switch.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
5C to 5F
Specified value
Data of page: 6 address: D1 is “01”
Note 1:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Perform this adjustment only when replacing the lens
block. When the microprocessor, circuit etc. is damaged,
don't perform this adjustment but check the steady shot
operations only.
Note 3:
With the lens not mounted, adjust the ND filter switch
while checking visually that the ND filter is surely
switched (free from incomplete engagement).
Switch setting
1) POWER ......................................................... CAMERA mode
RadarW
RadarW
RadarW
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
07
Check the data is “04”.
3
6
02
Check the data is “00”.
4
Set the ND FILTER to “1”.
5
6
D0
01
6
6
01
F1
Press PAUSE (Write) button.
(Note 4)
7
6
02
Check the data changes to
“01”.
8
6
D1
Check the data is “01”.
(Note 5)
9
6
01
00
Press PAUSE (Write) button.
10
Set the ND FILTER to “2”.
11
6
D0
02
12
6
01
F1
Press PAUSE (Write) button.
(Note 4)
13
6
02
Check the data changes to
“01”.
14
6
D1
Check the data is “01”.
(Note 5)
15
6
01
00
Press PAUSE (Write) button.
16
Set the ND FILTER to “3”.
17
6
D0
03
18
6
01
F1
Press PAUSE (Write) button.
(Note 4)
19
6
02
Check the data changes to
“01”.
20
6
D1
Check the data is “01”.
(Note 5)
21
6
01
00
Press PAUSE (Write) button.
22
Set the ND FILTER to “4”.
23
6
D0
04
24
6
01
F1
Press PAUSE (Write) button.
(Note 4)
25
6
02
Check the data changes to
“01”.
26
6
D1
Check the data is “01”.
(Note 5)
27
6
01
00
Press PAUSE (Write) button.
28
0
01
00
Note 4:
The adjustment data will be automatically input to page:
6F, address: 5C to 5F.
Note 5:
Adjustment error occurs if the data of page: 6, address:
D1 is “02”.
Summary of Contents for HDV HVR-Z7E
Page 496: ...144 Index Continued Zoom ring 27 ZOOM switch 27 ZOOM TRANS 46 ...
Page 497: ......
Page 498: ......