5-19
DSC-P31/P31M
6.
Mechanical Shutter Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
B8 to D7
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting”.
(Refer to page 5-14)
3
6
01
AD
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
5
6
AB
Check the data is “00”.
Note 2:
The adjustment data will be automatically input to page:
F, address: B8 to D7.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-13)
7.
Light Value Adjustment
RadarW
RadarW
RadarW
Adjust the standard LV value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 1 (Note
2) and page: F, address: 65
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
65 to 67
Specified Value
AE level 1: 0FE0 to 1020
AE level 2: 30 to 50
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting”.
(Refer to page 5-14)
3
6
01
0D
Press PAUSE button.
(Note 4)
4
6
02
Check the data changes to
“01”.
5
0
03
06
6
1
Check that the displayed data
(Note 2) satisfies the AE
level 1 specified value.
7
F
65
Check that the displayed data
satisfies the AE level 2
specified value.
Note 3:
The adjustment data will be automatically input to page:
F, address: 65 to 67.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
Release the data setting
performed at step 1.
(Refer to page 5-13)
Summary of Contents for DSC-P31
Page 94: ...DSC P31 P31M 4 45 4 46 SY 075 MS SOCET 6 5 4 3 2 1 11 21 ...
Page 99: ...DSC P31 P31M 4 55 FP 527 FLEXIBLE 4 56 FP 527 FLEXIBLE BOARD 11 ...
Page 167: ...DSC P31 P31M 11 12 SY 075 1 4 5 8 1 4 5 8 A K K A K A A K MS SOCET 12 22 6 5 4 3 2 1 ...
Page 174: ... 26 DSC P31 P31M Sony EMCS Co 9 929 948 82 2002D0500 1 2002 4 Published by DI Customer Center ...