DSC-WX50_L2
1-10
1-7.
ORNAMENTAL RING A OR BARRIER ASSY REPLACING METHOD
A
下図は当機種と本体の形状が異なります。
Note:
Note:
As for the figure below, this model and the shape
of the main body are different.
Barrier Assy
Claws
Claws
Hole
Barrier Assy
Claws
Claws
Barrier
Lever
3
4
Installation
1
2
5
Removal
1
2
3
4
Barrier Tape
Dent
Ornamental Ring A
Barrier Assy
Barrier Tapes
Barrier Tape
Barrier Tape
Ornamental Ring A
Solvent
Tweezers
Disengage the four claws and remove the Barrier Assy.
Fit the four claws while inserting the Barrier Lever into the hole and attach the Barrier Assy.
Affix two Barrier Tapes to the Barrier Assy so that the end of each Barrier Tape touches the dent.
Note:
The Barrier Tapes must not be wrinkled.
Peel off the release papers of the Barrier Tapes.
Install the Ornamental Ring A and press it lightly.
Turn on the power switch and extend the lens (WIDE end).
Detach the battery.
Apply alcohol to two gaps
A
of the Ornamental Ring A with tweezers or a fine-tipped stick as shown below.
Turn the Ornamental Ring A clockwise and counterclockwise to detach it.
1-8.
OPTICAL STEPPING MOTOR (F1430) REPLACING METHOD
Removal
1
2
Screw
Optical Stepping
Motor (F1430)
Solders
Install
1
2
Screw
Optical Stepping
Motor (F1430)
Groove
Projection
of worm
Solders
Remove the screw.
Unsolder the four locations of the Optical Stepping Motor (F1430) to detach it.
Solder the four locations of the Optical Stepping Motor (F1430).
Install the Optical Stepping Motor (F1430) with a screw.
*
Tightening torque = 0.0xx
±
0.0xN
•
m (0.x
±
0.xkgf
•
cm)
Note:
Install the Optical Stepping Motor (F1430) while fitting the groove with the projection of worm.
The changed portions from
Ver. 1.1 are shown in blue.