1-7
CSP-5000E
Operation
Proceed as follows to operate the System Controller.
1
Make necessary connections.
See page 8(EN).
2
Turn on the POWER switch.
• After about ten seconds, the system will boot up
and you will hear a buzzer sound.
• All monitors display the scene from the camera
connected to the VIDEO IN 1 terminal (as the
default setting).
• The date and time, the monitor number and the
camera number are displayed (as the default
setting).
Use the CSPK-5000E System Keyboard (not supplied)
to configure the system, program surveillance, and
make other settings.
12(EN)
Technical Information
Reference Signal
The following diagram shows the reference signal
block.
When VS singal is input from the SYNC IN
terminal
The signal input from the SYNC IN terminal is output
to the SYNC OUT terminal.
SYNC
IN
SYNC
OUT
75
Ω
Switches
automatically
Sync signal detection
SW501
INT
LL
75
Ω
75
Ω
SW501
When no signal is input from the SYNC IN
terminal
The internal reference signal or the line-lock reference
signal is output from the SYNC OUT terminal.
Use the slide switch SW501 inside the front panel to
determine the type of the signal to be output from the
SYNC OUT terminal.
LL
INT
Set the SW501 as follows:
INT : to output the internal reference signal
LL : to output the line-lock reference signal
Factory preset position is “INT.”
13(EN)