53
INT Mode
Sends the constant cyclical (2V) trigger pulse for E-DONPISHA to the XC-7500/8500CE camera module. The unit outputs
the updated video in every 1/30 sec. (EIA format) or 1/25 sec. (CCIR format). Set the TRIG switch on the front panel to INT.
In this mode, the video signal of the unit sets the field secured. Setting the internal switch S5-6 to ON switches the field.
Timing chart in the INT mode
Notes
• The field definition of this unit differs from that of the XC-
7500/8500CE camera module.
The field definition is as follows.
Falling edge of HD/VD is
correspond
not correspond
This unit
Field1
Field2
XC-7500 (EIA)
ODD field
EVEN field
XC-8500CE (CCIR)
EVEN field
ODD field
• Do not set the TRIG switch to EXT when switching the
field.
Trigger pulse
for camera
module
XC-7500 /
8500CE
video output1 (V1)
XC-7500 /
8500CE
video output2 (V2)
S5-6 is set to OFF
(factory setting) EIA /
CCIR output of this unit
WEN pusle
T
T=2V
1
1
2
2
3
3
1
(V1)
1
(V2)
2
(V1)
2
(V2)
Field1
Field2
Field1
Field2
3
(V1)
1
(V2)
Field2
1
(V1)
Field1
2
(V2)
Field2
2
(V1)
Field1
3
(V2)
Field2
Field1
1
(V1+V2)
1
(V1+V2)
2
(V1+V2)
2
(V1+V2)
3
(V1+V2)
VGA / S VGA output of
this unit
S5-6 is set to ON
EIA / CCIR output of this
unit