51
Image size
Monitor
screen
Converting the Signal Format
You can convert the video signal format input from the XC-
7500/8500CE camera module.
The output mode is set with the OUTPUT SEL switch on
the front panel.
• The external synchronization is not performed when the
unit outputs the signal in the VGA/S VGA format. The
external synchronization is automatically switched to the
internal synchronization.
• When connecting the XC-7500, the output image in the
CCIR format is under the monitor screen size as shown
below.
Notes
• This function converts the signal format, not the frequency
rate. When the trigger mode is in the normal mode, the
phenomena below could occur though they do not indicate
any faults.
When connecting the XC-7500
The same image is output on one field per 6 fields if output
is performed in the CCIR format.
When connecting the XC-8500CE
The image is not output on one field per 6 fields if output
is performed in the EIA format.
Camera module Trigger mode
Signal format
EIA
CCIR
VGA
SVGA
INT
XC-7500
EXT
normal
INT
XC-8500CE
EXT
normal
: Conversion available
: Conversion unavailable
• When connecting the XC-8500CE, the output video in the
EIA format is over the monitor screen size.
Image size
Monitor
screen
Summary of Contents for CMA-87