3-8
PDW-700/V1 (E)
(Continued)
Main
Sub
Time data
Maintenance
Drive
Description
code
code
display
logger
logger
95
503
←
O
O
Optical drive’s BDC (IC300/DR-606 board) error is detected during initial
check.
507
←
X
O
Adjustment data cannot be read from EEPROM in optical block assembly.
508
←
O
O
Hours meter data cannot be read from EEPROM in optical block assem-
bly.
509
←
O
O
Adjustment data cannot be read from optical drive’s EEPROM (IC4/
SE-857 board).
50A
←
O
O
Hours meter data cannot be read from optical drive’s EEPROM (IC4/
SE-857 board).
50C
←
O
O
Optical drive’s SYS PE (IC700/DR-606 board) configuration error is
detected.
50F
←
O
O
Cannot access SDRAM (IC301/DR-606 board) for Optical driver’s BDC
(IC300/DR-606 board).
513
←
O
O
Optical drive’s BDC (IC300/DR-606 board) cannot set the SDRAM mode.
51C
←
O
O
Optical drive’s BDC (IC300/DR-606 board) cannot reset free-run by SYS PE
(IC700/DR-606 board).
52C
←
O
O
Auto setting by SYS PE (IC700/DR-606 board) is disabled with power
control of optical drive’s BDC (IC300/DR-606 board).