5-13
PDW-700/V1 (E)
5-4-2. Master Gain
The Master Gain value can be saved in the REFERENCE FILE and in the SCENE FILE. When the
PDW-700 is used in a standalone manner, the hardware switches are prioritized, so the saved value
cannot be read out. When the PDW-700 is connected to the remote controller, the value of the master
gain can be read from each file and is retained until a change is made. (The value is retained even after
the power is turned off.) When the RM-B150 is connected, the hardware switches of the RM-B150 take
precedence.
5-4-3. Shutter
The values of SHUTTER ON/OFF, ECS frequency and SHUTTER SEL can be saved in the SCENE
FILE. When the PDW-700 is used in a standalone manner, the value of the ECS frequency and SHUT-
TER SEL can be read. The values are retained until a change is made. (The values are retained even after
the power is turned off.)
(The hardware switches are prioritized for SHUTTER ON/OFF, so the saved value cannot be read out.)
When the PDW-700 is connected to the remote controller, the value of SHUTTER SEL can be read out.
The value is retained until a change is made. (The values are retained even after the power is turned off.)