4-94
PDW-700/V1 (E)
4-10-13. SA ACTUATOR
This menu allows you to check the SA actuator motor.
Menu hierarchy:
[DRIVE MAINTENANCE]
→
[CHECK]
→
[OPTICAL BLOCK]
→
[SA ACTUATOR]
1.
A confirmation screen appears.
2.
Select “YES” by turning the MENU knob, and press
the MENU knob.
The result appears.
If failed:
The following screen appears.
The harness may be connected improperly or the optical
block may be defective.
SA ACTUATOR
CHECK START?
*YES
NO
SA ACTUATOR
CHECKING...OK
SA ACTUATOR
CHECKING...ERROR
4-10-12. TRACKING ACTUATOR
This menu allows you to check the tracking of the 2-axis
actuator.
Menu hierarchy:
[DRIVE MAINTENANCE]
→
[CHECK]
→
[OPTICAL BLOCK]
→
[TRACKING ACTUATOR]
1.
A confirmation screen appears.
2.
Select “YES” by turning the MENU knob, and press
the MENU knob.
Check that the 2-axis actuator moves several times.
.
If the actuator does not move or its movement is not
smooth, the harness may be connected improperly or
the optical block may be defective.
The result appears.
If failed:
The following screen appears.
TRACKING ACTUATOR
CHECK START?
*YES
NO
TRACKING ACTUATOR
CHECKING...OK
TRACKING ACTUATOR
CHECKING...ERROR