4-80
PDW-700/V1 (E)
FAN
Item
Setting
Function
FAN VOLT FIX
OFF/ON
Sets the fan mode
(Normally, set this to OFF and use the automatic control)
OFF: Temperature increase inside the unit is detected and the fan is
automatically controlled
ON: The fan is controlled by the fixed voltage (8 V)
(For the operation check of the fan)
FAN ROTATION DET
—/OK/NG
Display only
MEASURE
Item
Setting
Function
MEASUREMENT
OFF/S/N/MODU/RESO/
Selects the measurement mode
MODE
SENSE/REGI/DRANG
OFF
: It returns to OFF when the main power is turned on
S/N
: S/N ratio measurement mode
MODU
: Modulation degree measurement mode
RESO
: Resolution power measurement mode
SENSE : Sensitivity measurement mode
REGI
: Registration measurement mode
DRANG : Dynamic range measurement mode
MASTER BLACK
(
_
99 to 99)
Adjusts the master black level
(All of the R, G and B signal black levels are adjusted)
MASTER GAIN(TMP)
_
6/
_
3/0/3/6/9/12/18/24/
Sets the tentative gain value
30/36/42
S17 FAN TOP
FAN VOLT FIX : OFF
FAN ROTATION DET: OK
S18 MEASURE TOP
MEASUREMENT MODE: OFF
MASTER BLACK : 0
MASTER GAIN(TMP): 0dB