6-26
DNW-A22/A22P
1. Initial Data Setting
(1) Enter A3 : BETACAM PB ADJUST of the maintenance mode.
(2) Enter A30 : EQ VR.
(3) Set the specified data to all items of A30 : EQ VR.
(For setting data, refer to the table below.)
(4) To exit A30 : EQ VR, press the MENU button once.
(5) Enter A32 : DM VR 1.
(6) Set the specified data to all items of A32 : DM VR 1.
(For setting data, refer to the table below.)
(7) To exit A32 : DM VR 1, press the MENU button once.
(8) Enter A33 : DM VR 2.
(9) Set the specified data to all items of A33 : DM VR 2.
(For setting data, refer to the table below.)
(10) To exit A33 : DM VR 2, press the MENU button once.
Item of A3 :BETACAM ADJUST
Setting data for
Setting data for
DNW-A22
DNW-A22P
A30 : EQ VR
RF GAIN METAL-Y-A
55
8E
RF GAIN METAL-Y-B
55
8E
RF GAIN METAL-C-A
3F
6C
RF GAIN METAL-C-B
3F
6C
RF GAIN OXIDE-Y-A
72
9C
RF GAIN OXIDE-Y-B
72
9C
RF GAIN OXIDE-C-A
5A
81
RF GAIN OXIDE-C-B
5A
81
A32 : DM VR 1
EQ1 METAL-Y-A
79
80
EQ1 METAL-Y-B
79
80
EQ1 METAL-C-A
7C
90
EQ1 METAL-C-B
7C
90
EQ1 OXIDE-Y-A
A6
A1
EQ1 OXIDE-Y-B
A6
A1
EQ1 OXIDE-C-A
90
AD
EQ1 OXIDE-C-B
90
AD
A33 : DM VR 2
MAIN METAL-Y-A
CD
B7
MAIN METAL-Y-B
CD
B7
MAIN METAL-C-A
8E
8D
MAIN METAL-C-B
8E
8D
MAIN OXIDE-Y-A
A6
A8
MAIN OXIDE-Y-B
A6
A8
MAIN OXIDE-C-A
9E
9E
MAIN OXIDE-C-B
9E
9E
6-3. DM-89 Board Replacement