6-93
DNW-A22/A22P
1. Composite Output Level Adjustment
Measuring equipment:
Composite waveform/vector monitor (terminated with 75
Z
)
(1) METAL Y/C adjustment
Playback the color-bar signal portion (14:00 to 17:00) of the alignment tape CR5-1B or CR5-1B PS,
and perform the adjustment of each composite signal level.
(DNW-A22 CR5-1B, DNW-A22P: CR5-1B PS)
Equipment setting
Specifications
Adjustment point
WAVEFORM mode
DNW-A22: A = 714
±
7 mV (A = 100
±
1 IRE)
1
RV101/TBC-24(F-1)
DNW-A22P: A = 700
±
7 mV
VECTOR mode
Inside the corresponding frames
1
RV201/TBC-24(A/B-1)
(DP:
±
2.5
d
, DG:
±
2.5%)
(2) Eject the alignment tape CR5-1B/CR5-1B PS.
TBC-24 Board (Side A) (Suffix-13 and higher)
TBC-24 Board (Side A) (Suffix-11 and -12)
DNW-A22
DNW-A22P
TBC-24
MADE IN JAPAN
2
B
1
3
4
A
TP203
RV201
TP101
E501
TP601
A
C
D
E
F
G
A No.
LOT No.
S No.
RV500
RV501
RV300
E200
TP103
E100
RV402
RV400
TP300
TP401
TP500
TP201
TP202
RV200
RV202
TP102
TP400
RV102
RV101
TBC-24
MADE IN JAPAN
2
B
1
3
4
A
TP203
RV201
TP201
RV101
TP101
E501
TP601
A
C
D
E
F
G
A No.
LOT No.
S No.
RV500
RV501
RV504
E200
TP103
E100
RV402
RV400
TP300
TP401
TP500
RV300
6-7. TBC-24 Board Replacement
A
WAVEFORM mode
A
WAVEFORM mode
R
M
G
C
Y
G
Y
L
B
VECTOR mode
R
M
G
C
Y
G
Y
L
B
VECTOR mode