1-17
DNW-A22/A22P
Switches
Ref. No. Bit
Name
Description
Factory setting
S100
REEL POSITION
Press this switch when changing the reel position.
—————
This switch does not operate in the state of installing the cassette compertment.
S101
1
FLASH MEMORY
n
Do not change the setting of this switch during installation.
OFF (OPEN)
Select the operation mode of flash memory.
OFF (OPEN): Normal mode
ON (CLOSE): Writing mode
2
ANA AUTO-TRACKING
Select whether to enable auto tracking operation or not during playing
ON (CLOSE)
back the tape recorded based on the Betacam/Betacam SP format.
OFF (OPEN): Not operate (The tracking is controlled using RV100.)
ON (CLOSE): Operate
n
The Betacam SX tape playback is carried out by non-tracking operation.
3
ANA DISABLE
Select whether to prohibit analog Betacam tape playback or not.
OFF (OPEN)
OFF (OPEN): Enable
ON (CLOSE): Disable
4
SV ERR DISABLE
n
Do not change the setting of this switch during installation.
OFF (OPEN)
This switch selects whether to disable the detection of a malfunctional
error in a servo circuit.
OFF (OPEN): Enable (normal)
ON (CLOSE): Disable
S700
SYSTEM RESET
Press this switch when resetting system control operation.
—————
S1100
1
EXTENDED MENU
OFF (OPEN): Not display the extended menu of the set up menu
OFF (OPEN)
ON (CLOSE): Displays the extended menu of the set up menu
2
MAINTE MODE ACCESS OFF (OPEN): Not enter into maintenance mode from lower control panel
OFF (OPEN)
ON (CLOSE): Enters into maintenance mode from lower control panel
3 to 8 —————
Factory use
OFF (OPEN)
S1101
MAINTE MODE START
Press this switch when starting maintenance mode.
—————
S1102
n
Never change the settings of S1102 switch since each switch is set according to the characteristics of the unit.
But set this switch according to each unit when replacing the board.
1 to 6 MODEL ID SWITCH
1: OFF (OPEN)
2: OFF (OPEN)
3: OFF (OPEN)
4: ON (CLOSE)
5: ON (CLOSE)
6: OFF (OPEN)
7
J/SY
OFF (OPEN): Japan model
ON (CLOSE)
ON (CLOSE): Except Japan model
8
525/625
OFF (OPEN): 525/60 model
DNW-A22: OFF (OPEN)
ON (CLOSE): 625/50 model
DNW-A22P: ON (CLOSE)
S1900
1 to 8 —————
Factory use
OFF
(OPEN)
1-9. Switch and Shorting Plug Settings on PC Boards