![Sony Betacam SX DNW-A22 Maintenance Manual Download Page 179](http://html.mh-extra.com/html/sony/betacam-sx-dnw-a22/betacam-sx-dnw-a22_maintenance-manual_411167179.webp)
6-27
DNW-A22/A22P
(11) Enter A34 : DM VR 3.
(12) Set the specified data to all items of A34 : DM VR 3.
(For setting data, refer to the table below.)
(13) To exit A34 : DM VR 3, press the MENU button once.
(14) Enter A35 : DM VR 4.
(15) Set the specified data to all items of A35 : DM VR 4.
(For setting data, refer to the table below.)
n
Some setting data are different according to the board number suffix (XX of 1-648-541-XX) of DM-
89 board.
(16) To exit A35 : DM VR 4, press the MENU button once.
(17) Enter A36 : DM VR 5.
(18) Set the specified data to all items of A36 : DM VR 5.
(For setting data, refer to the table below.)
(19) To exit A36 : DM VR 5, press the MENU button once.
(20) Enter A3F : NV-RAM CONTROL of the maintenance mode.
(21) Execute “SAVE ALL ADJUST DATA”.
(22) Check that the message “Save Complete” is displayed on the video monitor.
(23) To exit A3F : NV-RAM CONTROL, press the MENU button once.
Item of A3 :BETACAM ADJUST
Setting data for
Setting data for
DNW-A22
DNW-A22P
A34 : DM VR 3
SUB METAL-Y-A
AF
B2
SUB METAL-Y-B
AF
B2
SUB METAL-C-A
70
91
SUB METAL-C-B
70
91
SUB OXIDE-Y-A
B2
BB
SUB OXIDE-Y-B
B2
BB
SUB OXIDE-C-A
A7
A8
SUB OXIDE-C-B
A7
A8
A35 : DM VR 4
GUARD BAND METAL-Y
1D (suffix-13 only: 38)
27 (suffix-13 only: 29)
GUARD BAND METAL-C
1C (suffix-13 only: 21)
23 (suffix-13 only: 16)
GUARD BAND OXIDE-Y
32 (suffix-13 only: 48)
2F (suffix-13 only: 3B)
GUARD BAND OXIDE-C
31 (suffix-13 only: 30)
29 (suffix-13 only: 16)
OMC DC METAL-Y
E4
E4
OMC DC METAL-C
D0
D0
OMC DC OXIDE-Y
D0
D0
OMC DC OXIDE-C
D0
D0
A36 : DM VR 5
DO TH METAL-Y
15
1E
DO TH METAL-C
14
1D
DO TH OXIDE-Y
2A
2A
DO TH OXIDE-C
28
28
ENV-TH-H
20
20
ENV-TH-L
10
10
6-3. DM-89 Board Replacement