K850
1203-2528 rev. 1
TROUBLESHOOTING
TROU
B
L
E
S
H
O
OTIN
G
Correct DCIO/SEPI Cable setup without the TRS Fixture.
Picture 12
Picture 13
Customized FM Radio Cable
STEP 1:
Use Cable according to Picture 14
Picture 14
Product Name: Test lead BNC-4mm 1,5m
Product Description: Test lead with 4 mm lab plugs at one end and a BNC plug at the other.
Manufacturer: PMK Germany
Location:
http://www.elfa.se/en/
or other supplier.
Part number: 46-310-40 (
Note:
This is ELFA part number
)
STEP 2:
Cut the Red lab plug according to Picture 15
Picture 15
STEP 3:
Use any Hands free (PHF) Cable and cut according to Picture 16
Picture 16
Note:
Minimum Cable length 40 cm.
STEP 4:
Use only wire connected to Pin2 and cut all rest wires according to Picture 17.
Use digital multimeter instrument (DMM) and perform diode measurement to select wire
connected to Pin2 at hands free system connector plug.
Picture 17
Equipment List
SEMC Troubleshooting Manual
6
(101)