9
Instruction for use | Supercal 5
2. Security
Safe and harmless operation of the calculator can only be guaranteed if the operating in-
structions have been read and the safety instructions contained therein have been observed.
Further information and data can be found in the products' catalogues and data sheets,
through your local representative, and on the Sontex homepage at www.sontex.ch.
All technical data without guarantee.
Subject to technical changes at any time.
In case of doubt, the text of the
English
Instructions For Use applies.
2.1 Personnel Qualification
The personnel responsible for installation, commissioning, diagnosis and maintenance must
meet the following conditions:
Trained personnel: Qualified to perform this function and activity.
Authorized by the plant operator.
Knowledge of the relevant standards and directives and familiar with national
regulations
Before starting work: Read and understand instructions and additional documentation
as well as certificates (depending on application).
Follow instructions and general conditions.
Training in the handling of hazards and risks during the installation and operation
of electrical devices and systems.
The operating personnel must meet the following conditions:
Instructed and authorized by the plant operator in accordance with the task
requirements.
Follow the instructions in this document.
2.2 Intended Use
Supercal 5 is an electronic device for recording energy flows in heating and cooling systems.
It can be used universally in industry, district heating and building services engineering.
The manufacturer is not liable for damage resulting from improper use. Modifications
and changes to the device must not be made.
The Supercal 5 may only be operated within the conditions specified on the nameplate
and in the technical specification.
Seals may not or only by authorized persons be removed. Country-specific and local
regulations as well as the manufacturer’s instructions are to be observed. The manu-
facturer assumes no responsibility for changes to the data relevant for calibration and
measurement if the factory seal has been broken.
If several heat meters are used in one billing unit, the same device types and installa-
tion positions should be selected to ensure that heat consumption is measured as fairly
as possible.
The feature of the calculator Supercal 5 for cooling applications with cooling liquids
water mixtures is exclusive to be used with the flow sensor Superstatic 440 (Not to be
used with mechanical flow sensors). If the feature cooling liquid (Glycol) water mixture
is enabled with the Superprog Windows and Superprog Android
2.3 Safety Instructions
2.3.1 Occupational Safety
When working on and with an electronic device:
Wear the necessary personal protective equipment under national
regulation.