Reference Monitors User Handbook
23
REFERENCE MONIT
ORS RM-2S4 & RM-2S10
REFERENCE MONITORS RM-2S4 & RM-2S10
1
Line-Up Level:
According to selected characteristic
Phase Metering
Type:
5-segment, indication at 0, 45, 90, 135 and 180 degrees
Remote Control
USB:
Slave device, 19200 baud
Serial:
RS232, 19200 baud, 3-wire connection
Alarm Outputs:
1. Audio underlevel/fail (latching)
2. Audio overlevel (latching)
3. Sustained phase error (latching)
4. AES/EBU input unlock (non-latching)
Open-collector outputs rated at 30V, 50mA maximum
Output low/conducting in normal condition (no alarm)
Control Inputs:
1. Mute audio
2. Dim audio
3. Alarm reset
Pull-to-ground to activate inputs
Status Indicators
LIMIT:
Indicates loudspeaker protection limiter is active.
CLIP:
Indicates internal digital clipping due to overlevel.
LOCK:
Indicates lock achieved on selected digital input(s).
OPT:
For future use.
Connectors
Audio Inputs (RM-2S4):
8 x XLR 3-pin female (balanced, may be unbalanced)
Audio Inputs (RM-2S10):
3 x D-type 25-pin female (balanced, may be unbalanced)
Audio Outputs:
XLR 3-pin male (balanced, may be unbalanced)
Headphones:
1/4” (6.35mm) A-gauge 3-pole stereo jack socket
USB:
Type B socket
Serial:
D-sub 9-pin female
Remote I/O:
D-sub 15-pin male
Mains Input:
Filtered 3-pin IEC male, continuously rated 85 - 264VAC,
47 - 63Hz, fused 2A, 60W peak, 30W average